Chapter 9 TL1 Commands

TL1 Commands and Autonomous Messages

F I N A L D R A F T - C I S C O C O N F I D E N T I A L

9.7.17 INIT-SYS

CommandINIT-SYS

Reboots the system.

SyntaxINIT-SYS:[<tid>]:<aid>:<ctag>::<ph>;

Example 9-19 INIT-SYS Command

Amp01:ONS15216 EDFA2> INIT-SYS:Amp01:ALL:1234::1;

Table 9-24 INIT-SYS Syntax Description

Parameter

Syntax

Description

 

 

 

aid

string

EQPT and ALL have same input effect.

 

EQPT

 

 

ALL

 

 

 

 

ph

integer

Level of initialization. Always 1.

 

1

 

 

 

 

9.7.18 REPT ALM DWDM

Command

REPT ALM DWDM

 

Reports when a DWDM alarm is logged or cleared (derived from cerent15216EdfaAlarmState).

Note The REPT ALM DWDM messages for Loss of Signal, Gain Out of Range, and Loss of Output Power are prioritized (in the order just listed) so that only one message can be delivered at one time. For example, if the ONS 15216 EDFA2 detects both a loss of input signal and a loss of output power at the same time, it will deliver only the Loss of Signal message to the user. This prioritized filtering of alarms does not occur with the SNMP delivery of alarms of the ONS 15216 EDFA2.

Syntax

<sid>

<date>

<time>

 

<almcde>

<atag>

REPT ALM DWDM

"<aid>:<ntfcncde>,<condtype>,<srveff>,<ocrdat>,<ocrtm>,,:<conddescr>"

;

Example 9-20 REPT ALM DWDM Message

Amp01 2001-06-18 14:50:44 ** 142 REPT ALM DWDM

"1:MJ,LOS,SA,6-18,14-50-44,,:\"Loss Of Signal\""

;

Cisco ONS 15216 EDFA2 Operations Guide

 

78-16033-01

9-25

 

 

 

Page 173
Image 173
Cisco Systems 15216 EDFA2 manual Init-Sys, Rept ALM Dwdm, CommandINIT-SYS, Eqpt ALL