Chapter 9 TL1 Commands

TL1 Commands and Autonomous Messages

F I N A L D R A F T - C I S C O C O N F I D E N T I A L

Example 9-44 RTRV-TH-EQPT Command and Response

Amp01:ONS15216 EDFA2> RTRV-TH-EQPT:Amp01:ALL:123::MAXCTMP;

Amp01 2001-06-08 09:00:05

M123 COMPLD "EQPT:MAXCTMP,,,60"

;

Table 9-48 RTRV-TH-EQPT Syntax Description

Parameter

Syntax

Description

 

 

 

date

yyyy-mm-dd

Date of origination of TL1 message.

 

 

 

time

hh:mm:ss

Time of origination of TL1 message.

 

 

 

aid

 

EQPT and ALL have same input effect.

 

 

 

 

EQPT

General parameters of the ONS 15216 EDFA2 (not directly

 

 

affecting optical signal or power bus).

 

 

 

 

ALL

Any or all of the preceding (command input only).

 

 

 

threshholdtype

 

Type of threshold or set point that is to be retrieved. A null

and

 

value is equivalent to ALL. Possible to specify values for one

thresholdvalue

 

or more of the following:

pairs

 

 

MAXCTMP

Maximum case temperature (cerent15216EdfaCtmpMax).

 

 

 

thresholdvalue can be between 20 and 70, with default of 65 in

 

 

units of °C.

 

 

 

 

MAXCTMPHYST

Maximum case temperature hysteresis

 

 

(cerent15216EdfaCtmpMaxHysteresis).

 

 

thresholdvalue can be between 0 and 10, with default of 1, in

 

 

units of °C.

 

 

 

 

MINCTMP

Minimum case temperature (cerent15216EdfaCtmpMin).

 

 

thresholdvalue can be between –10 and 10, with default of –5,

 

 

in units of °C.

 

 

 

 

MINCTMPHYST

Minimum case temperature hysteresis

 

 

(cerent15216EdfaCtmpMinHysteresis).

 

 

thresholdvalue can be between 0 and 10, with default of 1, in

 

 

units of °C.

 

 

 

Cisco ONS 15216 EDFA2 Operations Guide

9-58

78-16033-01

 

 

Page 206
Image 206
Cisco Systems 15216 EDFA2 Maximum case temperature cerent15216EdfaCtmpMax, Units of C, Maximum case temperature hysteresis