Chapter 8 Provisioning Using TL1

Set IP Address

F I N A L D R A F T - C I S C O C O N F I D E N T I A L

8.2 Set IP Address

Before connecting the ONS 15216 EDFA2 to a LAN, it is mandatory to set the ONS 15216 EDFA2 IP address through a local serial communication interface using the RS-232 (EIA/TIA-232) port on the front of the module.

Step 1 If you do not know the ONS 15216 EDFA2’s IP address, subnet mask, gateway address, or sid/tid name, contact your network administrator.

Step 2 At the command prompt, enter the ED-NE-GENcommand (see “ED-NE-GEN” section on page 9-19) according to the following syntax:

ED-NE-GEN:[<tid>]::<ctag>:::[NAME=<name>],[IPADDR=<ipaddr>],[IPMASK=<ipmask>],[DEFRTR=<def rtr>];

The name is the sid/tid name in the command line prompt. See Example 8-3.

Example 8-3 Setting IP Address, Subnet Mask, Gateway Address, and sid/tid Name Using TL1

sidtidname:ONS15216 EDFA2> ED-NE-GEN:::101:::NAME=Amp01,IPADDR=192.167.3.4,IPMASK=255.255.

255.0,DEFRTR=192.167.3.20;

Step 3 The system must be rebooted to make the IP address active. Use the INIT-SYScommand (see “INIT-SYS” section on page 9-25), as follows:

sidtidname:ONS15216 EDFA2> INIT-SYS::ALL:102::1;

8.3 Log In via LAN Port Using Telnet (Optional)

Provisioning of the ONS 15216 EDFA2 can be accomplished entirely through the RS-232 (EIA/TIA-232) port, so this step is optional. After an IP address is assigned, it may be easier to provision the ONS 15216 EDFA2 using Telnet. A Telnet client is needed for TL1 commands over IP. After connecting the ONS 15216 EDFA2 to the network through its RJ-45 LAN port (see “LAN Interface (Ethernet)” section on page 3-14), the user can configure the module to accept TL1 commands via Telnet using the following procedure:

Step 1 Connect to the LAN port on the ONS 15216 EDFA2. See “LAN Connection Procedure” section on page 3-15.

Step 2 Click the Microsoft Windows Start menu and select Run.

Step 3 In the text field, type the following:

telnet <ONS 15216 EDFA2 IP address> 3083

Specifying port 3083 ensures login through the TL1 shell. If no port is specified, the ONS 15216 EDFA2 responds in the shell that the ONS 15216 EDFA2 is set to. (TL1 is the default shell.)

Step 4 Log in again using Step 4 through Step 6 in “Log In via RS-232(EIA/TIA-232) Port Using HyperTerminal” section on page 8-1.

You are now connected to the ONS 15216 EDFA2 via Telnet.

Cisco ONS 15216 EDFA2 Operations Guide

 

78-16033-01

8-3

 

 

 

Page 139
Image 139
Cisco Systems manual 255.0,DEFRTR=192.167.3.20, SidtidnameONS15216 EDFA2 INIT-SYSALL1021