FINAL DRAFT - CISCO CONFIDENTIAL

6-19

CiscoONS 15216 EDFA2 Operations Guide
78-16033-01
Chapter6 ASH Commands
SNMP Commands
sysORLastChange.0 = 135;
sysORID.1 = { snmpBasicCompliance };
sysORID.2 = { rs232Compliance };
sysORDescr.1 = "";
sysORDescr.2 = "";
sysORUpTime.1 = 355925;
sysORUpTime.2 = 355925;
ifNumber.0 = 3;
ifIndex.300 = 300;
ifIndex.302 = 302;
ifIndex.350 = 350;
ifDescr.300 = "Intra-machine interface";
ifDescr.302 = "Ethernet Interface";
ifDescr.350 = "RS232 Interface";
ifType.300 = softwareLoopback;
ifType.302 = ethernetCsmacd;
ifType.350 = rs232;
ifMtu.300 = 0;
ifMtu.302 = 1500;
ifMtu.350 = 0;
ifSpeed.300 = 0;
ifSpeed.302 = 10000000;
ifSpeed.350 = 19171;
...
6.6.7 snmp row display Command

Command snmp row display

Syntax Description snmp row display {IP_address | local} row_name index

Displays a row. Use this command to obtain information to use with other commands. Type the

command, the first few letters of the attribute, and press Tab to view a list of attributes that can be set.

Type an attribute from the list to view its row data. See Example6-19.

Example6-19 snmp row display Command

ash:hostname:ONS15216 EDFA2> snmp row display local cerent15216Edfa
cerent15216EdfaCfgGroup
cerent15216EdfaPumpCfgEntry
cerent15216EdfaAlarmControl
cerent15216EdfaStatusGroup
cerent15216EdfaPumpStatusEntry
cerent15216EdfaAlarmEntry
cerent15216EdfaOpGroup
ash:hostname:ONS15216 EDFA2> snmp row display local cerent15216EdfaCfgGroup
CLASS CERENT-MIB.cerent15216EdfaCfgGroup ::=
{
cerent15216EdfaCfgSaved = true;
cerent15216EdfaLpoutSetpoint = 1000;
cerent15216EdfaLpoutDeviation = 200;
cerent15216EdfaLpoutHysteresis = 100;
cerent15216EdfaLOSThreshold = -2400;
cerent15216EdfaLOSHysteresis = 100;