1. For complete shut-down, turn remote wall switch to “OFF.”

LIGHTING INSTRUCTIONS — ELECTRONIC

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

A.When lighting the appliance, follow these instructions exactly.

B.BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Extinguish any open flame.

Open windows.

Do not light any appliance.

Do not touch any electrical switches.

Do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone.

If your gas supplier cannot be reached, call the fire department.

C.Use only your hand to turn the gas control lever. Never use tools. If the lever will not turn by hand, do not try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or an explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above on this page.

2.Turn remote wall switch to “OFF.”

3.Open lower control compartment door.

4.Verify main line shut-off valve is open.

 

 

ON/OFF Switch

CONTROL

OFF ON

IN

REITNIG

 

 

 

 

ISP

Front View

 

5.Turn the ON/OFF switch to “OFF”. Do not force.

6.Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow “B” in the safety information above on this page. If you do not smell gas, go to the next step.

7.Turn the ON/OFF switch to “ON”. Do not force.

8.Turn “ON” all electrical power to appliance (remote wall switch).

9.Close lower control compartment door.

TO SHUT OFF

1.Turn off all electrical power to the appliance (remote wall switch).

TO TURN OFF GAS TO APPLIANCE 3. Turn the ON/OFF switch to “OFF”. Do not force.

4. Close the main line shut-off valve.

2. Open lower control compartment door.

5. Close lower control compartment door.

18