Annually (Before the onset of the Burning Season)
Maintenance Task | Accomplishing Person | Procedure |
| |
|
|
|
| |
Inspecting/Cleaning Burner, Logs | Qualified Service Technician | Inspect valve and ensure it is properly operating. |
| |
and Controls |
| Check piping for leaks. Vacuum the control |
| |
|
| compartment, fireplace logs and burner area. |
| |
|
|
|
| |
Check Flame Patterns and Flame Height | Qualified Service Technician | Refer to Figure 7 |
| |
|
| or 9 |
| |
|
| verify the flame pattern and height displayed |
| |
|
| by the appliance conforms to the picture. |
| |
|
| Flames must not impinge on the logs. |
| |
|
|
|
| |
Inspecting/Cleaning Pilot and Burner | Qualified Service Technician | Refer to Figure 10 (SIT Millivolt), Figure 11 |
| |
|
| (Honeywell Millivolt) or Figure 12 (Elec- |
| |
|
| tronic) on page 8. Remove any surface |
| |
|
|
| ||
|
| the pilot nozzles, ignitor/flame rod and hood. |
| |
|
| Ensure the pilot flame engulfs the flame |
| |
|
| sensor as shown. |
| |
|
|
|
| |
Checking Vent System | Qualified Service Technician | Inspect the vent system at the top and at the |
| |
|
| base (within the firebox) for signs of blockage |
| |
|
| or obstruction. Look for any signs of disloca- |
| |
|
| tion of the vent components. |
| |
|
|
|
| |
Appliance Checkout | Qualified Service Technician | Perform the appropriate appliance checkout |
| |
|
| procedure detailed in this manual. |
| |
|
|
|
| |
Replacing Rockwool Ember Materials | Homeowner/Qualified Services Technician | Remove old ember materials and vacuum the |
| |
|
| screened rockwool placement area. Place new |
| |
|
| rockwool as described in this document. |
| |
|
|
|
| |
Periodically (After the Burning Season) |
|
|
| |
|
|
|
| |
Maintenance Task | Accomplishing Person | Procedure | ||
|
|
|
| |
Cleaning Firebox Interior | Homeowner | Carefully remove logs, Rockwool and volca- | ||
|
| nic stone if used. Vacuum out interior of the | ||
|
| firebox. Clean firebox walls and log grate. | ||
|
| Replace logs, Rockwool and volcanic stone | ||
|
| as detailed in this manual. | ||
|
|
|
| |
Check Flame Patterns and Flame Height | Homeowner | Refer to Figure 7 | ||
or 9 | ||||
|
| |||
|
| verify the flame pattern and height displayed by | ||
|
| the appliance conforms to the picture. Flames | ||
|
| must not impinge on the logs. | ||
|
|
|
| |
Checking Vent System | Homeowner | Inspect the vent system at the top and at the | ||
|
| base (within the firebox) for signs of block- | ||
|
| age or obstruction. Look for any signs of | ||
|
| dislocation of the vent components. | ||
|
|
|
| |
Cleaning Front Glass Enclosure Panel | Homeowner | Clean as necessary following the directions | ||
|
| provided in this manual. DO NOT TOUCH OR | ||
|
| ATTEMPT TO CLEAN GLASS WHILE HOT. | ||
|
|
|
|
5