Installing Line for Gas Logs

SR/SC Series "A" Woodburning Fireplace

Installing Line for Gas Logs

CFM Specialty Home Products fireplaces are designed to accept a 1/2" (13mm) gas line for installation of an approved gas appliance. (CFM Specialty Home Products manufactures a wide variety of gas logs for use in CFM Specialty Home Products fireplaces.)

Be sure to have the appliance installed in accordance with building codes.

Gas connection may enter from either left or right side of the fireplace.

Locate appropriate gas line in the outer casing of fireplace and remove insulation from gas line tube. (Fig. 26)

From inside the fireplace, locate the knockout on the firebrick -- be sure you are on the appropriate or "gas line" side of the fireplace. Using a flat bladed screw- driver or small chisel and hammer, carefully tap around the knockout until it loosens and falls out.

Install 1/2" (13mm) certified gas pipe through opening. After gas pipe installation is complete, use insulation that was removed from gas line tube to repack space around the pipe. Material should be inserted from outside of the fireplace and packed tightly to totally seal between the pipe and tube.

NOTE: Gas pipe should not come in contact with any wood structures until it has reached a point at least one (1) inch away from fireplace side.

NOTE: When installing an ANSI Z21.11.2 ventless appliance the finishing material used for the mantel must be rated at 250°F or greater.

BTU input of a gas appliance installed in fireplace should be rated less than 100,000 BTU/Hr.

Gas pipe installation is intended for connection to a decorative gas appliance only when (1.) incorporating an automatic shutoff device and (2.) complying with the Standard for Decorative Gas Appliances for Installation in Vented Fireplaces (ANSI Z21.60) or CSA draft requirements for Gas-Fired Log Lighters for Woodburning Fireplaces (Draft No. 4, August 1993).

Decorative gas appliance should be installed in accordance with the National Fuel Gas Code, ANSI Z223.1 (latest edition).

 

Hole in Outer Casing

 

Fireplace Top View

 

 

 

 

 

1"

 

 

Gas Line

Min.

Supply

 

 

Line

 

Tube

 

 

 

 

 

Ceramic

 

Repack

 

Knockout

 

Insulation

 

 

 

1/2"

 

Hole in

 

 

 

Casing

 

 

 

 

 

Ceramic

 

 

 

Knockout

 

 

 

(Both sides)

 

 

 

FP560

Fig. 26

Gas line access.

 

 

CAUTION: WHEN USING DECORATIVE GAS APPLIANCE, FLUE DAMPER MUST BE SET IN FULLY OPEN POSITION. IF YOU HAVE GLASS DOORS ON THE FIREPLACE, THEY MUST ALSO BE FULLY OPENED.

WARNING: DO NOT OPERATE AN

UNVENTED GAS LOG SET IN THIS

FIREPLACE WITH THE CHIMNEY RE-

MOVED.

WARNING: WHEN INSTALLING AN

UNVENTED AS LOG SET, THE CFM

Corporation MODEL AH3244BK OR

AH3244PB 4" ADJUSTABLE HOOD

MUST BE USED.

If installing an unvented gas log set, refer to statement below:

Only unvented gas logsets which have been found to comply with the Standard for Unvented Room Heaters, ANSI Z21.11.2, are to be installed in this fireplace.