SR/SC Series "A" Woodburning Fireplace
Chimney Supports
The chimney system is supported by the fireplace for vertical chimney heights less than 30' (9m) above the hearth. Chimney supports are required if the vertical height exceeds 30' (9m) with SK8 chimneys or 20' (6m) with
Angled chimney runs require a support every 6' (1.8m) in addition to the elbow straps. Chimney supports are used for this function. (Fig. 9)
Chase Installation
A chase is a vertical boxlike structure which encloses the fireplace and/or chimney. Chases are typically built on the outside of the house with fireplace opening cut into the outer wall of a room. (Page 5, Fig. 5)
If you need help in determining fireplace location or how the chimney system should be run, contact your Majestic Fireplaces dealer for assistance.
Chimney
Support Strap
SKCS8
FP284
Fig. 9 Chimney support installation
Installation
Insulating Fireplace Enclosure for Cold Climates
If you live in a cold climate, it is not required but highly recommended that you insulate fire- place enclosure to eliminate cold air penetration as much as possible.
Insulate base of fireplace with a noncombustible insulation rated for a minimum of 300°F. Insu- lating is very important for outside wall installa- tions over a concrete slab. If fireplace is in- stalled on a platform, insulation should be placed on top of the platform before fireplace is set. (Fig. 10)
When a fireplace is installed in a chase or on an outside wall, enclosure should be treated like any outside wall in a home. Insulation should be installed on the inside wall as well as the outside wall(s). In a chase, it is also a good idea to install a firestop at the first ceiling level above the fireplace and enclose the chase with sheeting material. Insulation may then be installed above sheeting material to assure the space around the fireplace is totally protected. (Fig. 5)
When installing the chimney, DO NOT caulk between outer pipe and firestop. It is vital that some air be allowed to flow through this very thin gap.
CAUTION: WHEN INSTALLING A FIRE- PLACE IN AN INSULATED ENCLOSURE, BE SURE ALL REQUIRED AIR SPACES ARE MAINTAINED. (Page 14, Fig. 20)
8 | 7412948 |