I
I
.i
Connecting air hose Lock the trigger. Slip the
air socket
of the
air hose
onto
the
air
fitting
on the nailer.
Be
sure
that
the
air
socket locks firmly into position when installed onto
the
air fitting. A hose coupling must be installed on
or near the tool
in such
a
way
that
the pressure reservoir
will
discharge at thetime
theair
supply coupling is dis-connected.
r Operation I
I
Release
the trigger
by turning the lock knob.
Place the driver guide
agianst the workpiece and
pull the trigger. Nails will be driven into the workpiece. When nails are depleted, the trigger
cannot be pulled because
a mechanism actuates. Load nails into the magazine, and the trigger
can now be pulled.
CAUTION
:
.The mechanism cannot actuate when the slide door is open.
So always lock the trigger by
turn-
Operating the tool without nails shortens the life of the tool and should be avoided.
ing
the lock knob to prevent accidental
firing
when the slide door is open.
Air exhaust Air exhaust direction can be changed easily by rotating
the exhaust cover. Change
it
when necessary.
Jammed nailer When the nailer becomes jammed, proceed as follows:
1. First, lock the trigger and disconnect the hose.
2.
Remove the three screws which secure the driver
3.
Remove the jammed
nail
from the ejection slot.
To reassemble the tool, perform the above operations
in reverse sequence.
guide. Remove the driver guide.
xhaust
cover
13