Makita G12010R manual - 14-, Style, Ampere Receptacle, AC plug, Description, Twist

Models: G12010R

1 44
Download 44 pages 31.38 Kb
Page 25
Image 25
Style

Check the amperage of the receptacles used referring to TABLE 1, and be sure not to take a current exceeding the specified amperage.

Be sure that the total wattage of all appliances dose not exceed the rated output of the generator.

Style

Ampere Receptacle

AC plug

Description

 

 

NEMA

NEMA

GFCI (Ground Fault

 

up to 20A

Circuit Interrupter)

 

5-20R

5-20P

Receptacle, duplex

 

 

 

 

 

 

(REC1)

 

up to 30A

NEMA

NEMA

Locking Receptacle

 

L5-30R

L5-30P

(REC2)

 

 

 

up to 30A

NEMA

NEMA

Locking Receptacle

 

L14-30R

L14-30P

(REC3)

 

 

 

up to 50A

 

Locking Receptacle

 

 

(REC4)

 

 

 

 

 

 

 

TABLE 1

 

 

Ampere ReceptacleAC plugWARNING

To take power out from the TWIST LOCK RECEPTACLE, insert the plug into the receptacle, and turn it clockwise to the lock position.

Be sure to ground the generator if the connected electrical device Is grounded.

NOTE :

TWIST

When the no-fuse breaker turns off during operation, the generator is over loaded or the appliance is defective. Stop the generator immediately, check the appliance and / or generator for overloading or detect and have repaired as necessary by Makita dealer or service shop.

14

Page 25
Image 25
Makita G12010R manual - 14-, Style, Ampere Receptacle, AC plug, Description, Twist