[CAUTION]
The duplex 120V receptacle is protected by a GFCI (Ground Fault Circuit Interrupter). GFCI shuts off the output current from the duplex 120V receptacle when a ground fault occurs in the generator or the appliance. Please note that other receptacles are not protected by GFCI.
GFCI RECEPTACLE
After starting the engine, check the GFCI for proper functioning by the following test procedure.
■
■
■
Push blue TEST button, The red RESET button will pop out exposing the word TRIP. Power is now off at the outlets protected by the GFCI, indicating that the device is functioning properly.
If TRIP dose not appear when testing, do not use the generator. Call a qualified electrician.
To restore power, push RESET button.
WARNING
If the RESET button pops out during operation, stop the generator immediately and call a qualified electrician for checking generator and the appliances.
(2) CONNECTING TO DOMESTIC CIRCUIT (HOUSE WIRING)
WARNING
This generator is neutral grounded type.
If a generator is to be connected to residential or commercial power lines, such as a
Failure in connection may result in death, personal injury, damage to generator, damage to appliances, damage to the building's wiring or fire.