(3) DC APPLICATION
The DC terminal is used only for charging 12 volt batteries. It provides up to 12V- 8.3A (100W) of maximum power.
CONNECTION OF CABLE :
■Connect positive (red) terminal on generator to positive (+) terminal on battery.
■Connect negative (black) terminal on generator to negative
■Both AC and DC output can be used at the same time if the total output is within rated output of the generator.
|
| ENGLISH |
| Red |
|
Black | - | + |
| ||
|
|
SAFETY PRECAUTIONS WHILE CHARGING
■An explosive hydrogen gas is discharged through vent holes in the battery during the charging process. Do not allow spark or open flame around the generator or battery during the charging process.
■Electrolyte fluid can burn eyes and clothing. Be extremely careful to avoid contact. If injured, wash the affected area immediately with large quantities of water and consult a doctor for treatment.
■When charging a large capacity battery or totally discharged battery, excessive current may force the DC breaker to turn off.
In such cases, use a battery charger to charge a large battery with AC output.
■Battery defects may cause the DC breaker to turn off. Check the battery before replacing the DC breaker.