7623833 FAN MOTOR REPLACEMENT ASSEMBLY FOR
| Installation Instructions |
| |
Kit Includes: |
|
|
|
Item | Description | Quantity Part Number | |
1 | Fan Motor | 1 | 2412553 |
2 | Fan Blade | 1 | 2416113 |
3 | Base Bracket | 2 | 6008901 |
4 | Slinger | 1 | 2415053 |
5 | Electrical Cover | 1 | 6629914 |
6 | Cable Tie | 2 | 5650423 |
7 | 4 | 5035651 | |
8 | 5/16 Lockwasher | 4 | 5573131 |
9 | 5/16 Flatwasher | 4 | 5573091 |
10 | 4 | 5429751 | |
11 | 2 | 5202163 | |
12 | #10 Starwasher | 2 | 5573203 |
13 | 10 | 5202063 | |
14 | Instruction Sheet | 1 | 8008133 |
15 | Label - Danger | 1 | 8130321 |
16 | Label - Caution | 1 | 8130361 |
17 | Strain Relief Bushing | 1 | 2512033 |
ALL WIRING MUST COMPLY WITH LOCAL AND NATIONAL ELECTRICAL CODES
1.Disconnect electrical power to the ice machine and the remote condenser.
2.Remove the old capacitor and bracket and the fan motor and mounting bracket assembly.
3.Drill four 7/32" diameter holes in the front panel and four 7/32" diameter holes in the back panel for mounting the new fan motor brackets, as shown on Sheet 3, Illustration A.
4.Assemble the slinger (Item 4) to the fan motor (Item 1) and then the fan blade (Item 2) over the slinger. Fasten the motor assembly to the motor mounting brackets with the four 5/16" machine screws, washers, and nuts (Items 7, 8, 9, 10), as shown on Sheet 3, Illustration A.
5.Mount the motor and bracket assembly in the condenser using the four
6.Use the cable ties (Item 6) to clamp the fan motor wires to the mounting brackets, as shown on Sheet 3, Illustration B.
7.Insert the fan motor wires through the bushing (Item 17) and snap bushing in the 7/8" diameter hole in the motor mounting bracket, as shown on Sheet 3, Illustration B.
8.Ground the fan motor and field wiring by connecting the green ground wires to the motor mounting bracket with the
starwashers should be placed between the bracket and the eyelet on the wire to insure grounding.
10.Connect the fan motor wires with the field wiring, as shown on the wiring diagram label on the back panel of the remote condenser.
11.Place the labels (Items 15 and 16) on the electrical cover (Item 5) and fasten the cover in place over the brackets and wiring with two
Manitowoc Ice, Inc.
2110 South 26 Street, P.O. Box 1720, Manitowoc, WI
Telephone
Web Site - www.manitowocice.com Rev. 05/03/99