Q MODEL ICE MACHINES
STACKING RELAY KIT 7628973
Installation Instructions
This relay kit is used to stop the operation of both stacked ice machines, when the bottom ice machine is turned off or in an
|
| Top Ice Machine |
STEP 1. | Disconnect power. | Drill 1/2 inch |
|
| holes and insert |
STEP 2. | Drill 1/2 inch (.50) hole in the back corner | bushings |
| posts of both ice machines in area indicated. | Wire Harness |
| Install two plastic black bushings into drilled | |
|
| |
| holes. |
|
STEP 3. Route wire harness through bushings from top electrical box to bottom electrical box.
Bottom Ice Machine
STEP 4. Using
Relay
Bottom Ice Machine
STEP 5. Wire the stacking kit relay according to wire diagram on reverse side.
A.Relay coil connects to the terminal board in the bottom ice machine.
B.Relay Contact is wired in series with the bin switch in the top ice machine.
1)Disconnect the wire of the bin switch, connected to ground, in the top ice machine.
2)Using new connector supplied, connect the wire disconnected from the ground to the new wire harness connected to the relay contacts.
3)Connect the other lead of wire harness to cabinet ground in the top ice machine (same ground that the bin switch wire used to be connected to).
Manitowoc Ice, Inc.
2110 South 26 Street, P.O. Box 1720, Manitowoc, WI | 8011463 |
Telephone | Sheet 1 of 2 |
Web Site - www.manitowocice.com | Rev. 11/27/06 |