J/B/G-0600 COMPRESSOR REPLACEMENT
Installation Instructions
NOTE: THIS REPLACEMENT IS ONLY FOR THE J, B, AND
1.Disconnect power to the ice machine at the electrical disconnect (moving the toggle switch to the off position will not disconnect line voltage).
2.Remove panels (top, front, left and right sides).
3.Recover refrigerant from ice machine.
4.Remove right side corner post (when facing the front of the machine) and back panel.
5. Remove wiring from compressor terminals.
6.Unsweat suction line at compressor port. Unsweat discharge and process lines at the T fitting and swage joint (or after “T” fitting, if remote) respectively.
NOTE: IF REPLACING COMPRESSOR IN A REMOTE ICE MACHINE, BE SURE TO UNSWEAT THE CONNECTION BETWEEN THE HPR VALVE AND THE PROCESS TUBING AT THE “T” FITTING.
Swage Joint
“T” Fitting
7.Remove compressor from machine. Make sure to crimp and braze shut ports to compressor.
8.Insert new compressor into the machine, as shown.
Manitowoc Ice, Inc.
2110 South 26 Street, P.O. Box 1720, Manitowoc, WI | 8006183 |
Telephone | Sheet 1 of 3 |