GSI 200 TIMER/BACK COVER REPLACEMENT
Installation Instructions
REPLACING THE TIMER CIRCUIT BOARD REQUIRES REPLACEMENT OF THE BACK PANEL
Timer Housing Back Cover
Timer Circuit Board
All Models
1.Install two (2) fresh AA batteries in timer housing noting proper polarity
RESET BUTTON
POSITIVE
TERMINALS
2.Verify timer circuit board is in the correct position. Snapping the control board under all four legs will correctly position the control board. The circuit board is incorrectly positioned if both lights (red and green) flash at the same time when the rear cover is installed.
PLACE TIMER BOARD ON
THE FOUR SUPPORTS
SNAP THE CONTROL BOARD UNDER
ALL FOUR LEGS TO SECURE
3.Verify the small key slots are on the right side when viewed from the front of the timer housing. Align sachet holder mounting plate holes with pins in the timer cover housing and snap into
place.
Attach Sachet
Mounting Plate to Back
Cover Pins
Upper Keyhole Slot
Lower Keyhole Slot
Small Keyhole Slots on right side when viewed from front
4.Use four
5.Attach sachet holder to mounting plate. Final assembly will be with sachet holder opening facing up.
a.Rotate sachet holder 90 clockwise.
b.Refer to table to determine if upper or lower keyhole slots are used. Place left side pin in the sachet mounting plate keyhole.
c.Rotate sachet holder 90 counterclockwise and place right side pin in keyhole slot.
d.Push sachet holder down into keyhole slots to secure.
FINAL POSITION IS
WITH OPENING
FACING UP
ROTATE 90 TO
ATTACH LEFT SIDE,
THEN ROTATE TO
FINAL POSITION TO
ATTACH RIGHT SIDE
Manitowoc Ice, Inc. |
|
2110 South 26th Street, P.O. Box 1720, Manitowoc, WI | 8014383 |
Telephone | Sheet 1 of 2 |
Web Site - www.manitowocice.com | 03/12/03 |