Section 2 | Installation Instructions |
Electrical Service
GENERAL
WARNING
All wiring must conform to local, state and national codes.
VOLTAGE
The maximum allowable voltage variation is ± 10% of the rated voltage at ice machine
WARNING
The ice machine must be grounded in accordance with national and local electrical codes.
FUSE/CIRCUIT BREAKER
A separate fuse/circuit breaker must be provided for each ice machine. Circuit breakers must be H.A.C.R. rated (does not apply in Canada).
MINIMUM CIRCUIT AMPACITY
The minimum circuit ampacity is used to help select the wire size of the electrical supply. (Minimum circuit ampacity is not the ice machine’s running amp load.)
The wire size (or gauge) is also dependent upon location, materials used, length of run, etc., so it must be determined by a qualified electrician.
Q1000 ICE MACHINE
| Voltage | Water Cooled | |
Ice | Phase | Maximum | Minimum |
Machine | Cycle | Fuse | Circuit |
|
| Circuit | Amps |
|
| Breaker |
|
Q1800 | 20 | 14.1 | |
|
|
|
|
Electrical Wiring Connections
WARNING
These diagrams are not intended to show proper wire routing, wire sizing, disconnects, etc., only the correct wire connections.
All electrical work, including wire routing and grounding, must conform to local, state and national electrical codes.
Though wire nuts are shown in the drawings, the ice machine field wiring connections may use either wire nuts or screw terminals.
Water Cooled Ice Machine 208-230/1/60
L1 | L1 |
N = 115V
OR
L2 =
GROUND
GROUND
ICE MACHINE | TO SEPARATE |
CONNECTIONS | FUSE/ BREAKER |
SV1258