Section 2 | Installation Instructions |
|
|
Water Service/Drains
WATER SUPPLY
Local water conditions may require treatment of the water to inhibit scale formation, filter sediment, remove chlorine, and improve taste and clarity.
Important
If you are installing a Manitowoc
Follow these guidelines to install water inlet lines:
•Connect to potable water supply only.
•Do not connect the ice machine to a hot water supply. Be sure all hot water restrictors installed for other equipment are working. (Check valves on sink faucets, dishwashers, etc.)
•If water pressure exceeds the maximum recommended pressure, obtain a water pressure regulator from your Manitowoc distributor.
•Install a water
•Insulate water lines to prevent condensation.
Important
The water inlet line is connected to the water valve. This valve is located just behind the front panel of the ice machine.
DRAIN CONNECTIONS
Follow these guidelines when installing drain lines to prevent drain water from flowing back into the ice machine and storage bin:
•Drain lines must have a 2.5 cm (1 inch) drop per 1 meter (40 inches) of run, and must not create traps.
•The floor drain must be large enough to accommodate drainage from all drains.
•Insulate the bin drain line to prevent condensation.
WATER SUPPLY AND DRAIN LINE SIZING/CONNECTIONS
!Caution
Plumbing must conform to state and local codes.
|
| Water |
| Water |
| Ice Machine | Tubing Size Up to Ice | |
| Temperature |
| Pressure |
| Fitting |
| Machine Fitting | |
|
|
|
|
| ||||
Ice Making | 10°C (50°F)Min.1 | 240 kPA (34.8 psi)Min.1 | 3/4” male hose | 0.95 cm (3/8”) minimum | ||||
Water Inlet | ° | ° | 2 | 620 kPA (89.9 psi)Max. | 2 | connection | 3 | inside diameter |
30 C (86 F)Max. |
|
|
|
|
| |||
Ice Making/ |
|
|
| 1.59 cm (5/8”) inside | 1.59 cm (5/8”) minimum | |||
Bin Water |
|
|
| diameter flexible | inside diameter | |||
Drain |
|
|
|
|
| hose |
| |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
1Min. = Minimum
2Max. = Maximum
3A 3/4” by