Installation Instructions

Section 2

Installation Instructions

 

 

Electrical Service

!Warning

All wiring must conform to local, state and national codes.

Voltage Phase

Electrical Rating

 

 

230/50/1

0.6kW

 

 

115/60/1

0.6kW

 

 

VOLTAGE

The maximum allowable voltage variation is ± 10% of the rated voltage on the ice machine model/serial number plate at start-up (when the electrical load is highest).

!Warning

The ice machine must be grounded in accordance with national and local electrical codes.

!Warning

Never use an extension cord. If an outlet is not within reach of the ice machine’s power cord, have a proper amperage outlet wired closer to the ice machine.

FUSE/CIRCUIT BREAKER

A separate fuse/circuit breaker must be provided for each ice machine.

NOTE: A disconnect means must be provided for field wiring.

ELECTRICAL RATING

The electrical rating is used to help select the wire size of the electrical supply. The wire size (or gauge) also depends on location, materials used, length of run, etc., so it must be determined by a qualified electrician.