Section 2

Installation Instructions

Electrical Service

WARNING

All wiring must conform to local, state and national codes.

Ice Machine

Voltage Phase

Air-Cooled

Model

Cycle

Electrical Rating

QM30

230/50/1

.6 KW /

2.6 Amps

QM30

115/60/1

.6 KW/

5.3 Amps

VOLTAGE

The maximum allowable voltage variation is ± 10% of the rated voltage at ice machine start-up (when the electrical load is highest).

WARNING

The ice machine must be grounded in accordance with national and local electrical codes.

WARNING

Never use an extension cord. If an outlet is not within reach of the ice machine’s power cord, have a proper amperage outlet wired closer to the ice machine.

FUSE/CIRCUIT BREAKER

A separate fuse/circuit breaker must be provided for each ice machine.

NOTE: A means of disconnect must be provided for field wiring.

ELECTRICAL RATING

The electrical rating is used to help select the wire size of the electrical supply. The wire size (or gauge) also depends on location, materials used, length of run, etc., so it must be determined by a qualified electrician.

FOR UNITED KINGDOM ONLY

As the colours of the wires in the mains lead of the appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:

The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol , or coloured green or green and yellow.

The wire coloured blue must be connected to the terminal which is marked with the letter N or coloured black.

The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red.

2-3

Page 11
Image 11
Manitowoc Ice QM30 Series Electrical Service, Voltage, FUSE/CIRCUIT Breaker, Electrical Rating, For United Kingdom only