Section 2

Installation Instructions

Water Service/Drains

WATER SUPPLY

Local water conditions may require treatment of the water to inhibit scale formation, filter sediment, and remove chlorine odor and taste.

Important

If you are installing a Manitowoc water filter system, refer to the Installation Instructions supplied with the filter system for ice making water inlet connections.

Follow these guidelines to install water inlet lines:

Connect to potable water supply only.

Do not connect the ice machine to a hot water supply. Be sure all hot water restrictors installed for other equipment are working. (Check valves on sink faucets, dishwashers, etc.)

If water pressure exceeds the maximum recommended pressure, obtain a water pressure regulator from your Manitowoc distributor.

Install a water shut-off valve for the ice making water lines.

Insulate water lines to prevent condensation.

DRAIN CONNECTIONS

Follow these guidelines when installing drain lines to prevent drain water from flowing back into the ice machine and storage bin:

Drain lines must have a 2.5 cm (1 inch) drop per 1 meter (40 inches) of run, and must not create traps.

The floor drain must be large enough to accommodate drainage from all drains.

Insulate the bin drain line to prevent condensation.

WATER SUPPLY AND DRAIN LINE SIZING/CONNECTIONS

CAUTION

Plumbing must conform to state and local codes.

 

Water

Water

Ice Machine

Tubing Size Up to Ice

 

Temperature

Pressure

Connection

Machine Fitting

Ice Making

10°C (50°F) Min.1

2.4 bar (35 psi) Min.1

3/4” male hose

0.95 cm (3/8”)

minimum inside

Water Inlet

30°C (86°F) Max.2

6.2 bar (90 psi) Max.2

connection3

diameter

 

 

 

 

Ice Making/Bin

---

---

1.59 cm (5/8”)

1.59 cm (5/8”)

inside diameter

minimum inside

Water Drain

 

 

flexible hose

diameter

 

 

 

1Min. = Minimum

2Max. = Maximum

3A 3/4” by 11-1/2 threads per inch to 14 threads per inch adapter is factory installed. Remove this adapter if 11-1/2 threads per inch connection is desired.

2-5

Page 13