F-4

THEORY OF OPERATION

F-4

 

Observe Safety Guidelines detailed in the beginning of this manual.

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

 

 

 

 

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

The line circuit breaker trips

 

OUTPUT PROBLEMS

1. Perform the Input Board

 

 

 

 

 

1.

Input power Bridge is shorted.

 

 

when power switch is “ON”

2.

Failed Electrolytic Capacitors.

Resistance Test.

 

 

 

 

3.

Failed Inverter IGBTʼs.

2. Perform the Inverter Board

 

 

 

 

Resistance Test.

 

 

 

 

 

 

 

 

The machine is dead, no output,

1.

No input power on line.

1. Restore correct Input power

 

 

no fan

 

2.

Line Switch failure.

2. Replace Line switch.

 

 

 

 

3.

Defective Input Board.

3. Perform Input Board Voltage

 

 

 

4.

Defective Inverter Board

4. Perform Inverter Board

 

 

 

 

 

 

Test.

 

 

 

 

 

 

Voltage Test.

 

 

 

 

 

 

 

 

The GREEN

LED is “ON” but

1. Thermal Protection has

1. Check Fan and Thermal

 

 

there is no output And yellow

 

tripped.

Protection Circuits.

 

 

thermal overload LED is “ON”

2. Logic Circuit Error on Control

2. Perform Input Board

 

 

 

 

 

Board.

Resistance and Input Board

 

 

 

3. ARFU System Damage on the

Voltage Tests

 

 

 

 

 

Input Board

3. The Control Board may be

 

 

 

 

 

 

faulty. Replace.

 

 

The YELLOW LED is “ON” and

1.

The machine is unable to cool

1. Turn the Power Switch OFF and

 

the RED and GREEN LEDʼs blink

 

itself.

wait several minutes for the

 

 

alternately

 

 

 

machine to cool. Turn the Power

 

 

 

 

 

Switch back ON and check for

 

 

 

 

 

proper fan operation.

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 1-888-935-3877.

INVERTEC® V155-S

Page 36
Image 36
Lincoln Electric V155-S service manual Resistance Test