TOC
TOC
MAINTENANCE | ||
SAFETY PRECAUTIONS |
| WARNING |
WARNING |
| |
|
|
Return to Section
Return to Master
ELECTRIC SHOCK can kill.
•Have an electrician install and ser- vice this equipment.
•Turn the input power off at the fuse box, disconnect supply lines and allow machine to sit for five minutes minimum to allow the power capaci- tors to discharge before working inside this equipment.
•Do not touch electrically hot parts.
Do not open this machine and do not introduce any- thing into its openings. Power supply must be discon- nected from the machine before each maintenance and service. After each repair, perform proper tests to ensure safety.
CAUTION
Power supply must be disconnected from the machine before each maintenance and service. Always use gloves in compliance with the safety standards.
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
INPUT FILTER CAPACITOR
DISCHARGE PROCEDURE
WARNING
For any maintenance or repair operations it is recom- mended to contact the nearest technical service center or Lincoln Electric. Maintenance or repairs performed by unauthorized service centers or personnel will null and void the manufacturers warranty.
WARNING
The machine has internal capacitors which are charged to a high voltage during
ROUTINE MAINTENANCE
The frequency of the maintenance operations may vary in accordance with the working environment. Any noticeable damage should be reported immediately.
•Check cables and connections integrity. Replace, if necessary.
•Clean the power source inside by means of low - pressure compressed air.
•Keep the machine clean. Use a soft dry cloth to clean the external case, especially the airflow inlet / outlet louvers.
THERMAL PROTECTION
The