Return to Section TOC
to Section TOC
Return to Master TOC
to Master TOC
TROUBLESHOOTING & REPAIR | ||
| INPUT FILTER CAPACITOR DISCHARGE PROCEDURE (CONTINUED) |
|
| FIGURE F.2 – CAPACITOR DISCHARGE LOCATIONS |
|
| INPUT BOARD |
|
CAPACITOR TERMINALS (4 places)
DC+
Return
Return to Section TOC
Return
Return to Master TOC
WARNING
ELECTRIC SHOCK can kill.
•Have an electrician install and service this equipment.
•Turn the input power off at the fuse box before working on equipment.
•Do not touch electrically hot parts.
•Prior to performing preventative maintenance, perform the following capacitor discharge procedure
PROCEDUREto avoid electric shock.
1. Disconnect power to the INVERTEC® V155-S.
2. Perform the Case Cover Removal Procedure, steps 1 thru 3.
3. Locate the Input Board.
4.Obtain a high resistance and high wattage resistor
5.Locate the two terminals DC+ and DC- on the Input Board. See Figure F.2.
6.Use electrically insulated gloves and insulated pli- ers. Hold the body of the resistor and connect the resistor leads across the two terminals. Hold the resistor in place for 10 seconds. DO NOT TOUCH CAPACITOR TERMINALS WITH YOUR BARE HANDS. See Figure F.3.
7.Check the voltage across the terminals of all capacitors with a DC voltmeter. Voltage should be zero. If any voltage remains, repeat this capacitor discharge procedure.
Return to Section TOC
Return to Master TOC
FIGURE F.3 – GLOVE, PLIERS & REISISTOR
INSULATEDPLIERS