TROUBLESHOOTING & REPAIR

F-33

 

RETEST AFTER REPAIR

 

Should a machine under test be rejected for any reason requiring the removal of any mechanical part that could affect the machineʼs electrical characteristics, or if any electrical components are repaired or replaced, the machine must be retested.

INPUT- SINGLE PHASE ONLY

 

 

 

 

 

 

 

 

 

 

 

 

 

Input Volts 50/60-HertzMax.

 

Input Current at Rated Output

Input Power at Rated Output

 

 

 

 

 

 

 

 

 

 

100%

 

30%

 

 

 

 

 

 

 

 

 

 

 

120VAC +/- 10%

 

34 A

 

 

2kw

 

3kw

230VAC +/- 10%

 

33 A

 

 

2kw

 

3kw

 

 

 

 

 

 

 

RATED OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Duty Cycle

 

Output Amps

Output Volts

 

 

 

 

Input Circuit

 

 

 

 

 

 

 

 

 

75A (stick)

23.0 Vdc

 

 

 

 

120 Vac

 

 

100%

 

 

105A (TIG)

14.2 Vdc

 

 

 

 

 

 

 

 

 

100A (stick)

24.0 Vdc

 

 

 

 

230 Vac

 

 

 

 

 

100A (TIG)

14.0 Vdc

 

 

 

 

 

 

 

 

 

 

100A (stick)

24.0 Vdc

 

 

 

 

120 Vac

 

 

30%

 

 

130A (TIG)

15.2 Vdc

 

 

 

 

 

 

 

 

 

145A (stick)

25.8 Vdc

 

 

 

 

230 Vac

 

 

 

 

 

155A (TIG)

16.2 Vdc

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output Current Range

 

 

Maximum Open Circuit Voltage

 

 

Type of Output

 

 

5-155 Amps

 

 

75 Volts Max.

 

 

 

DC

RECOMMENDED METERS FOR MACHINE OUTPUT TESTS

VOLTMETER: AC and DC True RMS Meter - Fluke 8922A or equivalent

AMMETER: Columbia Type AX AC or DC Tong Ammeter

IMPORTANT: IF OTHER TYPE METERS ARE USED RESULTS MAY NOT BE ACCURATE.

INVERTEC® V155-S

Page 65
Image 65
Lincoln Electric V155-S service manual INPUT- Single Phase only, Rated Output, Recommended Meters for Machine Output Tests