2.2.8. Electrical Requirements

The CMA-180 comes standard factory, wired for 3-phase operation. Check the electrical data plate to confirm this. If the account requires 1 phase, refer to “Electrical Requirements”, Section 1-A, for proper wiring instruction for conversion. Also check the wiring diagram to properly wire the terminal power block, tank heater, and booster heater for 1 phase (or 1B diagram below).

SINGLE PHASE POWER

NOTE: 80 amp service is required when CMA-180 is wired for single-phase with the booster heater. See “Electrical Requirements” section for DUAL 1-phase power supply. Circuit breaker requirement (1) 50 amp & 30 amp.

Figure 1-B

 

 

Single Phase

 

Single Phase

 

 

 

 

 

 

 

 

Rinse Booster Heater

 

Wash Tank Heater

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

Install booster heater

1.

Install wash heater bus

 

 

 

wires and bus bars as

 

bars as shown above.

2.

Connect wire #59 to

2.

Connect wire #15 to

 

 

 

heater L1.

 

heater L1.

3.

Connect wire #57 to

3.

Connect wire #17 to

 

 

 

heater L2.

 

heater L2.

 

 

 

 

 

 

 