3. Wiring Options

3. Wiring Options

3-Phase and 1 Phase

Wiring Options

Single-Source 220V 3-Phase (20 amp/12 g*)

(without Booster)

Single-Source 220V 3-Phase (50 amp/8 g*)

Single-Source Two-Source Single-Source

220V 1-Phase 220V 1-Phase 220V 1-Phase

(80 amp/4 g*) (50 amp/8 g*) (30 amp/10 G*)

(30 amp/10 g*)

(without booster)

*g=gauge

DISPENSER HOOK-UP

1.The power signal is 208/230 volts. The power block is labeled inside the control box. Conduit holes for both detergent & rinse are supplied on the control box.

2.A threaded (1/8”) injection point is provided on the final rinse Teflon mixing chamber located off the back of the machine.

3.A (7/8”) hole is provided in the tank for a probe access. It is located on the front side of the wash tank inside the heater cover.

MAIN POWER CONNECTION

Please refer to the machine data plate or choose one of the five (5) power connections illustrated above (1A). Electrical requirements are shown for machines with or without booster heater, three or single phase.

WARNING: Insure that the machine is properly grounded and complies to all local and national codes. Injury or death may occur from shock, if the machine is not properly grounded.

Install power supply wires, L1, L2 and L3 (3-Phase) to the appropriate terminals marked L1, L2, and L3 on the power block. (If applicable, the high or “wild” leg must be connected to the L2 Terminal.)