8. Wire Diagram for CMA-180 Booster Only

GROUND

RINSE SIGNAL{

DETERGENT {

GND

L3

L2

L1

PUMP

MOTOR

L2

PUMPWASH

CONTACTOR

T2

 

 

L1

 

 

T1

L3

HEATER

CONTACTOR

T3

L2

 

 

T2

L1

 

 

T1

L3

BOOSTER

HEATER CONTACTOR

T3

 

 

L2

 

 

T2

L1

 

 

T1

HI LIMIT

SWITCH

ADJ.

THERMOSTAT

12kW

BOOSTER

HEATER

5kW

WASH TANK

HEATER

MODEL CMA-180 INSTALLATION & OPERATION Rev. 2.03

Page 18

Page 19
Image 19
CMA Dishmachines manual Wire Diagram for CMA-180 Booster Only