Before Calling for Service

Section 5

 

 

 

To Correct

 

Problem

Possible Cause

 

Ice machine produces

Water level is low.

Be sure the overflow tube is fully

 

shallow or incomplete cubes,

 

seated to prevent water leakage.

 

or the ice fill pattern on the

 

See page 4-5.

 

evaporator is incomplete.

 

 

 

 

Water inlet valve filter screen is dirty.

Remove the water inlet valve and

 

 

 

clean the filter screen.

 

 

 

See page 4-6.

 

 

Water filtration is poor.

Replace the filter.

 

 

Hot incoming water.

Connect the ice machine to a cold

 

 

 

water supply. See page 2-5.

 

 

Ice thickness adjustment dial is not set

Adjust the ice thickness adjustment

 

 

properly.

dial. See page 3-2.

 

 

Incorrect incoming water pressure.

Water pressure must be 240-620 kPA

 

 

 

(34.8 - 89.9 psi).

 

 

Ice machine is not level.

Level the ice machine.

 

 

 

See page 2-2.

 

Low ice capacity.

Water inlet valve filter screen is dirty.

Remove the water inlet valve and

 

 

 

clean the filter screen.

 

 

 

See page 4-6.

 

 

Incoming water supply is shut off.

Open the water service valve.

 

 

The air filter is dirty.

Clean the air filter. See page 4-2.

 

 

The condenser is dirty.

Clean the condenser. See page 4-2.

 

 

Inadequate airflow at the front of the

Remove items blocking airflow at

 

 

ice machine.

the front of the ice machine.

 

 

Ice thickness adjustment dial is not set

Adjust the ice thickness adjustment

 

 

properly.

dial. See page 3-2.

 

5-2

Page 26
Image 26
Manitowoc Ice QM30 Series specifications Before Calling for Service Section, To Correct Problem Possible Cause