Water Level Probe

Maintenance

Section 4

 

 

Water Level Probe

1. Remove the water trough.

!Warning

Disconnect the electrical power to the ice machine at the electrical disconnect before proceeding.

2.The water level probe normally does not require removal for cleaning. The probe can be wiped and cleaned in place or proceed to step 3.

3.Pull the water level probe straight down to disengage.

4.Lower the water level probe until the wiring connector is visible. Disconnect the wire lead from the water level probe.

5.Remove the water level probe from the ice machine.

WATER LEVEL PROBE

SV3141

Water Pump

!Warning

Disconnect the electric power to the ice machine at the electric service switch box and turn off the water supply before proceeding.

1.Empty the water trough.

A.Move the toggle switch from OFF to ICE.

B.Wait 45 seconds.

C.Place toggle switch in OFF position.

WATER

PUMP

WATER

SV3091

PUMP BASE

Water Pump Removal

2.Remove the water trough.

3.The water pump normally does not require removal for cleaning. The water pump base can be wiped and cleaned in place or proceed to step 4.

4.Grasp pump and pull straight down on pump assembly until water pump disengages and electrical connector is visible.

5.Disconnect the electrical connector.

6.Remove the water pump assembly from ice machine.

7.Do not soak the water pump in cleaner or sanitizer. Wipe the pump and ice machine base clean.