Manley Labs INTEGRATED AMPLIFIER owner manual Specifications

Models: INTEGRATED AMPLIFIER

1 19
Download 19 pages 21.87 Kb
Page 17
Image 17
SPECIFICATIONS

 

SPECIFICATIONS

Vacuum Tubes:

 

8 x EL84, 2 x 6414

 

 

2 x 12AT7WA

Lamp type

 

1/4 X 1 1/4, 12 volt, .15 amp

Fuse type

120VAC operation: MDL 3 AMP / 250 Volt SLO-BLO

 

240VAC operation: MDL 2 AMP/ 250 Volt SLO-BLO

 

B+ FUSES (2): MDL 1/4 AMP/250 Volt SLO-BLO

Gain

 

37 dB max

 

 

185mv input=50w output

Signal to noise

 

Typically 87 dB A WGT 20-20K

 

 

(69 dB unweighted)

Frequency Response

 

15 Hz to 40 kHz @ - 1 dB

Distortion @ 5 watts

 

.25 % @ 5W, 1 kHz (-55 dB)

Volume control "Left / right tracking"

.25 dB

Input Impedance

 

100 Kohm

Output Power

 

50 Watts each channel

 

 

(1.5% THD @ 1kHz, both channels driven)

Output Impedance

 

Optimized for 4-8 ohm speakers

 

 

(5 ohm design)

Damping Factor

 

10

Power Consumption (idle)

170 Watts (1.4A @120VAC)