Henny Penny 600, 500 manual Warnings And, ERROR MESSAGES Continued, Error Codes, Cause, Correction

Models: 500 600

1 100
Download 100 pages 58.33 Kb
Page 32
Image 32
3-5. WARNINGS AND

 

 

 

Model 500/600

 

3-5. WARNINGS AND

 

 

ERROR MESSAGES (Continued)

 

 

 

ERROR CODES

 

DISPLAY

CAUSE

CORRECTION

 

“E-5”

Controls sensing 405°F

Have heat components and temperature probe

 

“FRYER TOO

or above

checked

 

HOT”

 

 

 

 

 

 

 

“E-6” (A or B)

Faulty temperature probe or

Have temperature probe and connection

“FRYER TEMP

connection

checked

 

SENSOR

 

 

 

FAILED”

 

 

 

 

 

 

 

“E-10”

Peanut oil temperature too hot,

Reset high limit per Operating Components;

 

“HIGH LIMIT

drain valve opened while heat was

Section; check peanut oil temperature for

 

TRIPPED”

on, or faulty high limit

overheating; have heat components checked if

 

 

 

high limit continues to trip

 

 

 

 

 

“E-15”

Drain is open or faulty microswitch

Close drain; have drain microswitch checked

 

“DRAIN IS

 

if error code persists

 

OPEN”

 

 

 

 

 

 

 

“E-25”

Wrong or faulty elements or wiring

Have electrical supply, wiring, and elements

 

“HEAT AMPS

problem.

checked

 

WERE TOO

 

 

 

HIGH”

 

 

 

(500 fryer only)

 

Because of the seriousness of this error code,

 

 

 

turn the COOK/PUMP switch OFF and back

 

 

 

to COOK to cancel.

 

 

 

 

 

“E-26”

Faulty contactors or PC board

Have the contactors and PC board checked

 

“HEAT AMPS

 

 

 

ARE

 

 

 

LOCKED ON”

 

 

 

(500 fryer only)

 

This error code could be displayed even with

 

 

 

the COOK/PUMP switch turned OFF. Unplug

 

 

 

fryer or shut off the wall circuit breaker to

 

 

 

disconnect electrical power to fryer.

 

 

 

 

 

E-41”

Memory scrambled; an individual

Turn the COOK/PUMP switch OFF and back

 

“SYSTEM

product program may be scrambled;

to COOK; if error code persists, have the PC

 

DATA LOST”

ex: “E-41 -2- DATA LOST”; this

board checked or re-initialized

 

 

means product #2 program is

 

 

 

scrambled

 

 

 

 

 

 

E-41”

Memory scrambled; an individual

Turn the COOK/PUMP switch OFF and back

 

“SYSTEM

product program may be scrambled;

to COOK; if error code persists, have the PC

 

DATA LOST”

ex: “E-41 -2- DATA LOST”; this

board checked or re-initialized

 

 

means product #2 program is

 

3-12

scrambled

205

 

Page 32
Image 32
Henny Penny 600, 500 manual Warnings And, ERROR MESSAGES Continued, Error Codes, Cause, Correction