following report is displayed:

 

Model 500/600

5-3. DIAGNOSTIC MODE

If the fryer has witnessed two or more low voltage warnings today, the

DETAILS (Continued)

following report is displayed:

“D4: CAN’T TEST”

“D4: HEAT CAPACITY”

“D4: DUE TO”

“D4: VOLTAGE”

“D4: PROBLEMS”

Otherwise, if the assessed heat capacity rating is presently “good” and there has been at most one heat-up today that failed to achieve the expected rate, the following report is displayed:

“D4: HEATING”

“D4: CAPACITY”

“D4: IS FINE”

Otherwise, if the heat capacity is presently assessed as “bad”, or presently assessed as “good” but two or more heat-ups today have not reached the expected heat-up rate, the following report sequence is generated:

“D4: YOU HAD 75%”

“D4: SLOW HEATS”

“D4: TODAY”

(Press “D4: CAN’T TEST” )

“D4: HAVE 20%”

“D4: SLOW HEATS”

“D4: THIS OIL”

(Press “D4: PROBLEMS” )

“D4: HAD 0%”

“D4: SLOW HEATS”

“D4: LAST OIL”

(Press “D4: HEATING” )

If the heat capacity is assessed as bad (low heat-up rate on last heat- up, and on three of the last four heat-ups), then the heating coils are suspect and the following message is displayed:

“D4: CHECK COILS,”

“D4: CONTACTORS,”

“D4:AND WIRING”