Henny Penny CFA Pressure Fryer Electric Model Gas Model
OPERATOR’S MANUAL
Page
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS
Keep appliance area free and clear from combustibles
Model 500/600
Page
TABLE OF CONTENTS
Section
Preventive Maintenance Schedule
TABLE OF CONTENTS
1-1. INTRODUCTION
SECTION 1. INTRODUCTION
NOTICE is used to highlight especially important information
1-2. PROPER CARE 1-3. ASSISTANCE 1-4. SAFETY
2-1. INTRODUCTION
SECTION 2. INSTALLATION
pressure fryer
Do not puncture the fryer with any objects such
Continued
7. Close the front door
2-2. UNPACKING
INSTRUCTIONS
2-3. SELECTING THE FRYER LOCATION
2-2. UNPACKING INSTRUCTIONS
2-5. VENTILATION OF FRYER
2-3. SELECTING THE FRYER LOCATION Continued 2-4. LEVELING THE FRYER
Model 500/600
2-4. VENTILATION 0F FRYER Continued
Do not use cast iron fittings
2-6. GAS SUPPLY
To avoid possible serious personal injury
2-6. GAS SUPPLY Continued
Provisions should be made for moving the fryer for cleaning and
servicing. This may be accomplished by
2-7. GAS LEAK TEST
Model 500/600
LIGHTINGAND SHUTDOWN PROCEDURE
2-8. GAS PRESSURE REGULATOR SETTINGS 2-9. GAS PILOT & BURNER
Lighting Procedure - Solid State Ignition
Shutdown Procedure
Shutdown Procedure
2-9. GAS PILOT & BURNER LIGHTING AND SHUT DOWN PROCEDURES Continued
Lighting Procedure - Solid State Ignition
kPa for natural gas 10.0 inch 2.49 kPa for propane. If adjustment is
The gas regulator is preset at the factory at 3.5 inch water column
ADJUSTMENT
+ ground service. The gas fryer is factory equipped with a grounded
Wire
Supply Wiring and Fusing for Electric Fryer
Phase
2-12. ELECTRICAL REQUIREMENTS ELECTRIC FRYER
SECTION 3. OPERATION 3-1. OPERATING COMPONENTS
Frypot Lid Gasket Deadweight Assembly Safety Relief Valve
Condensation Drain Pan Lid Latch
3-1. OPERATING COMPONENTS Continued Safety Relief Valve Ring
Pressure Gauge Solenoid Valve Drain Valve Drain Interlock Switch
Filter Drain Pan Filter Union Filter Valve Contactors Model
Gas Control Valve Model Spindle Assembly Lid Limit Stop
3-1. OPERATING COMPONENTS Continued High Limit
Function
Description
Continued
3-2. OPERATING CONTROLS
Control Decal
twice. “CLOCK SET” then
3-3. CLOCK SET
Continued
3-3. CLOCK SET
14. Press
Language Selection
3-4. DIAGNOSTIC MODE AND SPECIAL FUNCTIONS
Peanut Oil Life Function
Manual Mode
3-4. DIAGNOSTIC MODE AND SPECIAL FUNCTIONS Continued
Status Mode
Peanut Oil Filter Enforcement
“*INFO MODE*” shows on display. Press or to access the
Information Mode
3-4. DIAGNOSTIC MODE AND SPECIAL FUNCTIONS Continued
WARNINGS
3-5. WARNINGS AND ERROR MESSAGES
DISPLAY
CAUSE
ERROR CODES
ERROR MESSAGES Continued
3-5. WARNINGS AND
CAUSE
ERROR MESSAGES Continued
ERROR CODES
3-5. WARNINGS AND
DISPLAY
Electric Model
When using solid shortening, it is recommended to melt
3-6. FILLING OR ADDING PEANUT OIL
Gas Model
3-6. FILLING OR ADDING
PEANUT OIL Continued
When using solid shortening, it is recommended to melt
Do not bypass the Melt Cycle unless enough shortening
3-7. BASIC OPERATION
Continued
3-7. BASIC OPERATION
10. Once out of the Melt Cycle
LID MUST BE LATCHED PROPERLY OR PRESSUR
3-7. BASIC OPERATION Continued
IZED SHORTENINGAND STEAM MAY ESCAPE FRYPOT. SEVERE BURNS WILL RESULT
DO NOT LIFT HANDLE OR FORCE LID LATCH
FOLLOW THE INSTRUCTIONS BELOW TO AVOID
3-8. CARE OF PEANUT OIL
SHORTENING OVERFLOWING THE FRYPOT, WHICH
COULD RESULT IN SERIOUS BURNS, PERSONAL
SHORTENING
3-9. FILTERING OF
causing breading to stick and burn
Scraping the electric fryer elements, or the curved portion
Use caution to prevent burns caused by splashing hot
RINSE HOSE WHEN THE MAIN POWER SWITCH IS
peanut oil
ONLY CONNECTAND DISCONNECT THE FILTER
3-9. FILTERING OF SHORTENING Continued
3-10. FILTER PUMP PROBLEM PREVENTION
3-12. CHANGING THE FILTER ENVELOPE
3-11. FILTER PUMP MOTOR THERMAL PROTECTOR
3-12. CHANGING THE FILTER ENVELOPE Continued
3-13. CLEANING THE FRYPOT
CLEANER IN FRYPOT. WATER UNDER PRESSURE
3-13. CLEANING THE FRYPOT Continued
BECOMES SUPERHEATED. WHEN LID IS OPENED
DO NOT CLOSE LID WITH WATER AND/OR
Failure to follow this caution could cause component failure
Do not spray the unit with water, such as, with a garden hose
3-13. CLEANING THE FRYPOT Continued
If using Henny Penny fryer cleaner, continue to the next steps
FRYPOT Continued
3-13. CLEANING THE
fryer
NEW OR USED
MAINTENANCE
SECTION 4. PREVENTIVE MAINTENANCE
Procedure
When “FILTER LOCKOUT”
At the end of each day, the deadweight valve assembly must be
4-2. CLEANING THE DEAD
WEIGHT VALVE
cleaned as follows
4-3. REMOVAL AND CLEANING OF SAFETY RELIEF VALVE
TEMPERATURE PROBE
1. Heat peanut oil and stir completely until peanut oil temperature
4-4. REVERSING LID
GASKET
4-6. LIMIT STOP ADJUSTMENT Step Step
4-7. LUBRICATE LID SPINDLE AND BALL SEAT
4-8. CHECK & TIGHTEN ELEMENT SPREADER BARS Model 500 only
Page
5-1. INTRODUCTION
SECTION 5. TROUBLESHOOTING
Cause
Problem
Correction
COOKING SECTION
Problem
COOKING SECTION Continued
Cause
Correction
Cause
Problem
Correction
COOKING SECTION Continued
Cause
Problem
Correction
COOKING SECTION Continued
PRESSURE SECTION
POWER SECTION
Problem
Cause
FILTER SYSTEM SECTION
PRESSURE SECTION Continued
Problem
Cause
HEATING OF PEANUT OILSECTION
FILTER SYSTEM SECTION Continued
Problem
Cause
HEATING OF PEANUT OILSECTION Continued
AND WIRING” shows on
COILS, CONTACTORS
Problem
Accessing Diagnostic Mode
5-3. DIAGNOSTIC MODE
“ *DIAGNOSTIC* “ “ *REPORT* “
DETAILS
“ LT - - - - - + - - - - - DK”
5-3. DIAGNOSTIC MODE DETAILS Continued
D 1 ColorAdjustment
“D2 THIS OIL IS “ “D2 4 DAYS OLD “
D 2 Oil Wear Report
“D2 THIS OIL IS “ “D2 16% USED “
5-3. DIAGNOSTIC MODE DETAILS Continued
DETAILS Continued
D 3 Line Voltage Performance Report
Voltage Report for Today
“D3 YOU HAD 3” “D3 LOW VOLTAGE” “D3 WARNINGS” “D3 TODAY”
“D3 FACILITY” “D3 OR UTILITY” “D3 PROBLEM”
“D3 PROBLEM”
“D3 CHECK CORD,” “D3 WIRING,” “D3AND BREAKER”
“D3ARE OTHER”
the following sequence is displayed
If one or more low voltage warnings have been detected before today
“D3 BEFORE TODAY” “D3 27 LOW VOLT” “D3 WARNINGS” “D3 ON THIS OIL”
“D3 MIN VOLTAGE” “D3 BEFORE TODAY” “D3 = 85%”
“D4 CHECK COILS,” “D4 CONTACTORS,” “D4AND WIRING”
“D4 PROBLEMS”
following report is displayed
“D4 CAN’T TEST” “D4 HEAT CAPACITY” “D4 DUE TO” “D4 VOLTAGE”
“D4 HEATER COILS “
“D4 CHECK “ “D4 CONTACTORS, “ “D4 CONNECTIONS, “ “D4 AND WIRING “
“D4 APPEAR OK “
D 5 Cook Times Slow Cooks Report
“D5 SOME SLOW” “D5 COOKS TODAY” “D5 MAYBE DUE TO” “D5 VOLTAGE OR”
“D5 COIL PROBLEMS”
“D5 COOKING SLOW” “D5 TODAY”
“D5 “FILET” Product Name
“D5 OVERSIZED”
“D5 POSSIBLE”
“D5 OR FROZEN”
“D5 BATCH OF”
“D6 ON THIS OIL”
“D6 BEFORE TODAY,” “D6 COOKED” “D6 BEFORE READY” “D6 8 TIMES”
“D6 LAST OIL,” “D6 COOKED” “D6 BEFORE READY” “D6 24 TIMES”
D 7 “Stopped Too Soon” Report
“D7 ON THIS OIL”
“D7 BEFORE TODAY “ “D7 3% OF LOADS” “D7 WERE STOPPED” “D7 TOO SOON”
“D7 LAST OIL” “D7 5% OF LOADS” “D7 WERE STOPPED” “D7 TOO SOON”
D 8 “Beeped *DONE* Too Long” Report
“D8 ON THIS OIL”
“D8 BEFORE TODAY “ “D8 7% OF LOADS” “D8 BEEPED ‘DONE’” “D8 TOO LONG”
“D8 LAST OIL” “D8 6% OF LOADS” “D8 BEEPED ‘DONE” “D8 TOO LONG”
D 9 Irregular Loading Report
“D9 LOOKS OK”
“D9 LOADING”
“D9 TODAY”
“D9 IRREGULAR”
If no products have a failed to detect rate of more than 5%, the
Loading Report for Previous Batch of Peanut oil
controller shows
“D9 LOADING” “D9 LOOKED OK” “D9 PREVIOUS OIL”
“10 DO NOT MATCH”
“10 PROD’S 123456”
“10 ORIG. VALUES”
“10ALL CFAITEMS”
“10 ALL HC ITEMS”
DIAGNOSTIC MODE
“10 3 HC ITEMS”
INFORMATION MODE
3. HEAT-UP’S
5-4. INFORMATION MODE DETAILS
4. COOK DATA
DISPLAYEXAMPLE
DISPLAYEX
5-4. INFORMATION MODE
DETAILS
FUNCTION
5-4. INFORMATION MODE
6. PREV DAY - SUN
DETAILS
FUNCTION
5-4. INFORMATION MODE
7. 7-DAY TOTALS
DETAILS
FUNCTION
5-4. INFORMATION MODE
8. OIL DATA current batch resets by Clean-Out Mode
DETAILS
Press to step through the following data
FUNCTION
DETAILSpeanut oil Press to step through the following data
DISPLAYEX
TOT WEAR
DETAILS
10. INP AVHDSFM
5-4. INFORMATION MODE
12. POT TMP
11. OUTP H* P
“12. POT TMP temp.”
13. CPU TMP
15. AC VOLTS 98%
14. ANALOG
16. AMPS 33 33
5-4. INFORMATION MODE
Model 500/600
Model 500/600
G L O S S A R Y
HENNYPENNYPRESSUREFRYERS
gas fryers only
shortening level also referred to as level indictor lines
Model 500/600
Model 500/600
head fryers. the lid assembly includes spindles
gas fryers only
gas fryers only
place see lid latch
Model 500/600
gas fryers only
gas fryers only
see ignition modules
Model 500/600
gas fryers only
HENNY PENNY
Electric
4 HEAD PRESSURE FRYER
Electric
Revised 01/01/07
LIMITED WARRANTY FOR HENNY PENNY EQUIPMENT
Model 500/600
P.O.Box
Henny Penny Corporation
Eaton,OH
Toll free in USA