2-12. ELECTRICAL REQUIREMENTS (ELECTRIC FRYER)

2-12. ELECTRICAL REQUIREMENTS (ELECTRIC FRYER)

Model 500/600

The electric fryer requires 208 or 240 volt, three phase, 50/60 Hertz service. The power cord may be already attached to the fryer or provided at installation. Check the data plate behind the front door to determine the correct power supply.

This fryer must be adequately and safely grounded (earthed) or electrical shock could result. Refer to local electrical codes for correct grounding (earthing) procedures or in absence of local codes, with The National Electrical Code, ANSI/NFPA No. 70-(the current edition). In Canada, all electrical connections are to be made in accordance with CSA C22.1, Canadian Electrical Code Part 1, and/or local codes.

To avoid electrical shock, this appliance must be equipped with an external circuit breaker which will disconnect all ungrounded (unearthed) conductors. The main power switch on this appliance does not disconnect all line conductors.

A separate disconnect switch with proper capacity fuses or breakers must be installed at a convenient location between the fryer and the power source. It should be an insulated copper conductor rated for 600 volts and 90o C. For runs longer than 50 feet (15.24 m), use the next larger wire size.

Supply Wiring and Fusing for Electric Fryer

 

 

 

 

Supply

Min.

 

 

 

 

Wire

Fuse

Volts

Phase

KW

Amps

Size

Size

208

Single

13.50

65

2

90

208

Three

13.50

38

6

50

240

Single

13.50

61

3

70

240

Three

13.50

35

6

50