ERROR CODES

 

 

 

 

 

Model 500/600

 

3-5. WARNINGS AND

 

 

 

 

ERROR MESSAGES (Continued)

 

 

 

 

 

ERROR CODES

 

 

 

DISPLAY

CAUSE

CORRECTION

 

 

E-41”

Memory scrambled; an individual

Turn the COOK/PUMP switch OFF and back

 

“SYSTEM

product program may be scrambled;

to COOK; if error code persists, have the PC

 

DATA LOST”

ex: “E-41 -2- DATA LOST”; this

board checked or re-initialized

 

 

 

means product #2 program is

 

 

 

 

 

scrambled

 

 

 

 

 

 

 

 

“E-46”

Faulty eprom or PC board

Turn the COOK/PUMP switch OFF and back

 

“DATA SAVE

 

to COOK; if error code persists, have the PC

 

FAILED”

 

board checked or re-initialized

 

 

 

 

 

 

“E-47”

Failure of 12 volt DC supply

Turn the COOK/PUMP switch OFF and back

 

“ANALOG

on the I/O board

to COOK; if the

and

DO NOT

 

SYSTEM

 

 

 

 

 

OR 12 VOLT

 

light up when the 8888’s are displayed, have the

 

FAILED”

 

I/O board replaced

 

 

 

 

Amp sensors plugged in backwards

Have positions of amp sensors checked

 

 

Faulty PC board

Have control panel replaced

 

 

 

 

 

 

“E-48”

Failure of 12 volt DC supply

Turn the COOK/PUMP switch OFF and back

 

INPUT

on the I/O board

to COOK; if the

and

DO NOT

 

SYSTEM

 

 

 

 

 

ERROR”

 

light up when the 8888’s are displayed, have the

 

 

 

I/O board replaced

 

 

 

 

Faulty PC board

Have control panel replaced

 

 

 

 

 

 

“E-70 A”

Missing or broken wire in pins 1 and

Have jumper wire between pins 1 and 2

 

“FAN VAC

2 of P11 connector, or faulty

checked

 

 

 

JUMPER

connector

 

 

 

 

MISSING”

Faulty I/O board

Have I/O board checked and replaced if

 

 

 

 

 

necessary

 

 

 

 

 

 

 

“E-70 B”

Faulty COOK/PUMP switch

Have COOKPUMP switch checked, along

 

“PWR SW

or switch wiring; faulty

with its wiring; have I/O board checked

 

OR WIRES

I/O board

 

 

 

 

FAILED”

 

 

 

 

 

 

 

 

 

“E-92”

Blown 24 volt controller fuse, or

Have the 14-pin cable connector checked or

 

“24 VOLT

bad 14-pin cable connection

have the fryer checked for a short to ground in

 

FUSE”

 

components such as the drain switch, solenoid,

 

 

 

or high limit and wiring

 

 

 

 

Stuck or clogged solenoid valve

Have solenoid checked and cleaned

205

 

 

 