Henny Penny 600, 500 Outp H* P, Pot Tmp, “12. POT TMP temp.”, Cpu Tmp, Information Mode, Details

Models: 500 600

1 100
Download 100 pages 58.33 Kb
Page 90
Image 90
11. OUTP H* P_

 

 

Model 500/600

5-4. INFORMATION MODE

11. OUTP H* P_

DETAILS

This mode displays the status of components and outputs. If the output

 

signal is detected, an identifying letter is displayed (see below), followed

 

by an “*”. If the output is off, “_” is displayed.

 

H = Heat output

 

P = Pressure output

 

If heat is on, “H*” shows in display. If heat is off, “H_” shows in

 

display. If controls senses a problem with the heat output, “H*” shows

 

in display, with the “*” flashing.

 

If pressure is on, “P*” shows in display. If pressure is off, “P_” shows

 

in display. If controls senses a problem with the pressure output, “P*”

 

shows in display, with the “*” flashing.

 

Press

to view the “amps” status of each output.

 

“H\/” and “P\/” in the display means the amps are good. Aflashing “X”

 

behind the H or P means a problem exists.

 

Press

to view the no connect/ground (“NC/GD”) status of each

 

output. This monitors a possible problem with the relays on the output

 

PC board.

 

“H\/” and “P\/” in the display means everything on the output PC board

 

is good. Aflashing “X” behind the H or P means a problem exists.

 

Press

to view the outputs and inputs (see step 10) together.

 

Press

to continue onto the POT TMP reading.

 

12. POT TMP

 

This step shows the present peanut oil temperature. The display shows

 

“12. POT TMP (temp.)”.

 

Press

to continue onto the CPU TMP reading.

 

13. CPU TMP

 

This step shows the present PC board temperature.

 

Press

to continue onto the ANALOG reading.

5-34

 

303

Page 90
Image 90
Henny Penny 600, 500 manual Outp H* P, Pot Tmp, “12. POT TMP temp.”, Cpu Tmp, Information Mode, Details