Henny Penny 500, 600 manual Removal And Cleaning Of Safety Relief Valve

Models: 500 600

1 100
Download 100 pages 58.33 Kb
Page 51
Image 51
4-3. REMOVAL AND

4-3. REMOVAL AND

CLEANING

OF SAFETY RELIEF VALVE

Figure 3-13

safety valve

Model 500/600

The safety relief valve should be cleaned once a year. Figure 3-13.

DO NOTATTEMPT TO REMOVE SAFETY VALVE WHILE FRYER IS OPERATING, OR SEVERE BURNS OR OTHER INJURIES WILL RESULT.

DO NOT DISASSEMBLE OR MODIFY THIS SAFETY RELIEF VALVE. TAMPERING WITH THIS VALVE COULD CAUSE SERIOUS INJURIES AND WILL VOID AGENCYAPPROVALSANDAPPLIANCE WARRANTY.

1.Open the lid and then remove the deadweight valve cap and deadweight.

2.Use a wrench to loosen the relief valve from the pipe elbow, turning counterclockwise to remove.

3.Clean the inside of the pipe elbow with hot detergent.

Turn the relief valve towards the rear of the fryer when reinstalling relief valve.

4.Immerse the safety relief valve in a soap water solution for 24 hours. Use a 1:1 dilution ratio. The valve cannot be disassembled. It is factory preset to open at 14-1/2 pounds of pressure. If it does not open or close, it must be replaced.