4-2. CLEANING THE DEAD

 

Model 500/600

4-2. CLEANING THE DEAD

At the end of each day, the deadweight valve assembly must be

WEIGHT VALVE

cleaned as follows:

DO NOTATTEMPT TO REMOVE DEADWEIGHT CAP

WHILE FRYER IS OPERATING. SEVERE BURNS OR

OTHER INJURIES WILL RESULT.

Step 3

Step 5

Step 6

1.Turn the COOK/PUMP switch to OFF. Be sure all pressure has been released and open the lid.

2.Unscrew the deadweight cap and remove the cap and deadweight.

Deadweight cap may be hot. Use protective cloth or glove, or burns could result.

Failure to clean the deadweight assembly daily could result in the fryer building too much pressure. Severe injuries and burns could result.

3.Clean the exhaust tube with stainless steel brush (Henny Penny part number 12147).

4.Clean the deadweight cap and weight in hot detergent water. Make certain to thoroughly clean the inside of the valve cap and the deadweight.

5.Clean the deadweight orifice and the inside of the deadweight body with a clean lint-free cloth.

6.Dry the deadweight and deadweight cap.

7.Replace the deadweight and hand tighten deadweight cap.