2-10.

 

 

Model 500/600

2-10.

PRESSURE

The gas regulator is preset at the factory at 3.5 inch water column (0.87

 

REGULATOR

kPa) for natural gas (10.0 inch (2.49 kPa) for propane). If adjustment is

 

ADJUSTMENT

necessary, contact your local independent Henny Penny distributor.

 

(GAS ONLY)

 

2-11.

ELECTRICAL

The gas fryer requires 120 single phase, 60 Hertz, 10 or 5 amp, 2 wire

 

REQUIREMENTS

+ ground service. The gas fryer is factory equipped with a grounded

 

(GAS FRYER)

cord and plug for your protection against shock and should be plugged

 

 

into a 3 prong grounded receptacle. Awiring diagram is located behind

 

 

the front door.

Do not disconnect the ground (earth) plug. This fryer must be adequately and safely grounded (earthed) or electrical shock could result. Refer to local electrical codes for correct grounding (earthing) procedures or in absence of local codes, with The National Electrical Code, ANSI/NFPA No. 70-(the current edition). In Canada, all electrical connections are to be made in accordance with CSA C22.1, Canadian Electrical Code Part 1, and/or local codes.

To avoid electrical shock, this appliance must be equipped with an external circuit breaker which will disconnect all ungrounded (unearthed) conductors. The main power switch on this appliance does not disconnect all line conductors.