2-8. GAS PRESSURE REGULATOR SETTINGS

Model 500/600

2-8. GAS PRESSURE REGULATOR SETTINGS

2-9. GAS PILOT & BURNER

LIGHTINGAND SHUTDOWN PROCEDURE

Gas Control Valve

“ON/OFF” Selector

The gas pressure regulator on the automatic gas valve is factory set as follows:

Natural: 3.5 inches water column

Propane: 10.0 inches water column

The gas pressure regulator has been set by Henny Penny and is not to be adjusted by the user.

Lighting Procedure - Solid State Ignition

1.Turn main power switch to OFF position.

2.Move “ON/OFF” selector on gas control valve to OFF position.

3.Wait a sufficient length of time to allow any gas which may have accumulated in the burner compartment to escape (at least 5 minutes).

4.Move “ON/OFF” selector on gas control valve to ON position.

5.Turn main power switch to ON position.

6.Wait about 45 seconds for the burner to light.

7.Listen for the gas burner ignition.

It will be an audible sound due to the gas igniting at the gas jets within the burner.

8.The burner lights and operates until the shortening temperature reaches a preset temperature, and when tempearture light goes out, set timer for desired length of time.

Do not leave the thermostat on for more than 10 seconds without shortening in the frypot or damage to the frypot may result.

9.The frypot should be cleaned per the instructions in Section 3.

10.The frypot must be filled to the proper level with shortening. Refer to Filling orAdding Shortening Section.

Shutdown Procedure

1.Move “ON/OFF” selector on gas control valve to OFF position.

2.Turn main power switch to ON position.

710