17. RED Gain Data
Function
The external control equipment changes the RED Gain Data of the plasma monitor.
Transmission Data |
|
| |
DFH 80H 60H 7FH 04H | DATA00 to DATA03 CKS | ||
DATA00: | USER PICTURE Gain Flag | 01H | |
DATA01: | RED Gain Flag | 01H | |
DATA02: | RED Gain 1 (Bias) | D8H: | |
|
|
|
|
|
| FFH: | |
|
| 00H: 0 | |
|
|
|
|
|
| IEH: +30 | |
DATA03: | RED Gain 2 (Drive) | D8H: | |
|
|
|
|
|
| FFH: | |
|
| 00H: 0 | |
|
|
|
|
|
| IEH: +30 | |
ACK |
|
|
|
|
|
| |
7FH 60H 80H 7FH 02H | DATA00 DATA01 CKS | ||
DATA00: | USER PICTURE Gain Flag | 01H | |
DATA01: | RED Gain Flag | 01H |
18. GREEN Gain Data
Function
The external control equipment changes the GREEN Gain Data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 04H | DATA00 to DATA03 CKS | ||
DATA00: | USER PICTURE Gain Flag | 01H | |
DATA01: | GREEN Gain Flag | 02H | |
DATA02: | GREEN Gain 1 (Bias) | D8H: | |
|
|
|
|
|
| FFH: | |
|
| 00H: 0 | |
|
|
|
|
|
| IEH: +30 | |
DATA03: | GREEN Gain2 (Drive) | D8H: | |
|
|
|
|
|
| FFH: | |
|
| 00H: 0 | |
|
|
|
|
|
| IEH: +30 | |
ACK |
|
|
|
|
|
| |
7FH 60H 80H 7FH 02H | DATA00 DATA01 CKS | ||
DATA00: | USER PICTURE Gain Flag | 01H | |
DATA01: | GREEN Gain Flag | 02H |
19. BLUE Gain Data
Function
The external control equipment changes the BLUE Gain Data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 04H | DATA00 to DATA03 CKS | ||
DATA00: | USER PICTURE Gain Flag | 01H | |
DATA01: | BLUE Gain Flag | 03H | |
DATA02: | BLUE Gain1(Bias) | ||
|
|
|
|
|
| ||
|
| 00H: 0 | |
|
|
|
|
|
| IEH: +30 | |
DATA03: | BLUE Gain2(Drive) | D8H: | |
|
|
|
|
|
| ||
|
| 00H: 0 | |
|
|
|
|
|
| IEH:+30 | |
ACK |
|
|
|
|
|
| |
7FH 60H 80H 7FH 02H | DATA00 DATA01 CKS | ||
DATA00: | USER PICTURE Gain Flag | 01H | |
DATA01: | BLUE Gain Flag | 03H |
20. Multi Screen Select
Function
The external control equipment selects single screen mode or multi screen mode of the display.
Transmission Data
DFH | 80H 60H 07H | 01H DATA00 | CKS |
DATA00: | Multi Screen |
|
|
| 00: Single screen |
|
|
01:Side by side 1 (Left screen bigger)
02:Side by side 2 (Left screen smaller)
03:Picture in Picture sub screen L
04:Picture in Picture sub screen R
ACK
The display returns the following ACK.
7FH | 60H 80H 07H | 01H DATA00 | CKS |
DATA00: | Multi Screen |
|
|
| 00: Single screen |
|
|
01:Side by side 1 (Left screen bigger)
02:Side by side 2 (Left screen smaller)
03:Picture in Picture sub screen L
04:Picture in Picture sub screen R
When other commands (except POWER OFF) are sent while the screens are switching with this command, the other command will be returned as “Not Available” until screen switching is finished.
44