17. RED Gain Data

Function

The external control equipment changes the RED Gain Data of the plasma monitor.

Transmission Data

 

 

DFH 80H 60H 7FH 04H

DATA00 to DATA03 CKS

DATA00:

USER PICTURE Gain Flag

01H

DATA01:

RED Gain Flag

01H

DATA02:

RED Gain 1 (Bias)

D8H: -40

 

 

 

 

 

 

FFH: -1

 

 

00H: 0

 

 

 

 

 

 

IEH: +30

DATA03:

RED Gain 2 (Drive)

D8H: -40

 

 

 

 

 

 

FFH: -1

 

 

00H: 0

 

 

 

 

 

 

IEH: +30

ACK

 

 

 

 

 

 

7FH 60H 80H 7FH 02H

DATA00 DATA01 CKS

DATA00:

USER PICTURE Gain Flag

01H

DATA01:

RED Gain Flag

01H

18. GREEN Gain Data

Function

The external control equipment changes the GREEN Gain Data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 04H

DATA00 to DATA03 CKS

DATA00:

USER PICTURE Gain Flag

01H

DATA01:

GREEN Gain Flag

02H

DATA02:

GREEN Gain 1 (Bias)

D8H: -40

 

 

 

 

 

 

FFH: -1

 

 

00H: 0

 

 

 

 

 

 

IEH: +30

DATA03:

GREEN Gain2 (Drive)

D8H: -40

 

 

 

 

 

 

FFH: -1

 

 

00H: 0

 

 

 

 

 

 

IEH: +30

ACK

 

 

 

 

 

 

7FH 60H 80H 7FH 02H

DATA00 DATA01 CKS

DATA00:

USER PICTURE Gain Flag

01H

DATA01:

GREEN Gain Flag

02H

19. BLUE Gain Data

Function

The external control equipment changes the BLUE Gain Data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 04H

DATA00 to DATA03 CKS

DATA00:

USER PICTURE Gain Flag

01H

DATA01:

BLUE Gain Flag

03H

DATA02:

BLUE Gain1(Bias)

D8H:-40

 

 

 

 

 

 

FFH:-1

 

 

00H: 0

 

 

 

 

 

 

IEH: +30

DATA03:

BLUE Gain2(Drive)

D8H: -40

 

 

 

 

 

 

FFH:-1

 

 

00H: 0

 

 

 

 

 

 

IEH:+30

ACK

 

 

 

 

 

 

7FH 60H 80H 7FH 02H

DATA00 DATA01 CKS

DATA00:

USER PICTURE Gain Flag

01H

DATA01:

BLUE Gain Flag

03H

20. Multi Screen Select

Function

The external control equipment selects single screen mode or multi screen mode of the display.

Transmission Data

DFH

80H 60H 07H

01H DATA00

CKS

DATA00:

Multi Screen

 

 

 

00: Single screen

 

 

01:Side by side 1 (Left screen bigger)

02:Side by side 2 (Left screen smaller)

03:Picture in Picture sub screen L

04:Picture in Picture sub screen R

ACK

The display returns the following ACK.

7FH

60H 80H 07H

01H DATA00

CKS

DATA00:

Multi Screen

 

 

 

00: Single screen

 

 

01:Side by side 1 (Left screen bigger)

02:Side by side 2 (Left screen smaller)

03:Picture in Picture sub screen L

04:Picture in Picture sub screen R

When other commands (except POWER OFF) are sent while the screens are switching with this command, the other command will be returned as “Not Available” until screen switching is finished.