TROUBLESHOOTING

ENGLISH

TROUBLESHOOTING

7Before considering it as a failure

In case of trouble with this component, first check the following before calling for service. What seems to be a serious malfunction is often due to a simple operation mistake.

If the trouble is not fixed after making the following checks, contact the place of purchase, your nearest Marantz dealer, our customer service center, or our repair service center.

Phenomenon

Cause

Actions

 

The power cord is disconnected.

Check the power cord connection.

Power is not supplied.

 

If the OPERATE indicator is flashing, turn the

The protection circuit is activated.

power OFF then back ON again after 1 minute

 

 

 

or more.

 

Speaker connection is incomplete.

Check the speaker cable connection.

 

Input cable connection is incomplete.

Check the input cable connection.

 

Use of the connected player is wrong.

Confirm the operation methods, referring to

 

the instruction manual of the player.

 

 

 

The INPUT SELECTOR knob is not set

Set the INPUT SELECTOR knob properly.

 

correctly.

 

 

The VOLUME knob is set to minimum.

Turn the VOLUME knob to set the proper

 

level.

 

 

Power is supplied, but no sound is

 

Set the SPEAKER A/B buttons properly,

The SPEAKER buttons are set to OFF.

according to the SPEAKER terminals to which

heard from the speakers.

 

the speakers are connected.

 

 

 

 

If “ATT” is displayed on the display, press the

 

The ATT. muting function is activated.

ATT. button on the main unit or remote control

 

unit, or increase/decrease the volume level, in

 

 

 

 

order to cancel the attenuation function.

 

The protection circuit has been activated, and

Adjust the volume again.

 

the volume has been automatically muted.

 

 

An error message is displayed.

Set the ID number properly, referring to the

 

table in “ERROR MESSAGES”, on page 26.

 

 

 

Speaker connection is incomplete.

Check the speaker cable connection.

Sound is heard from the left or right

The set values for the volume (LEVEL

 

speakers only. Or, the volume from

TRIM) and sound quality (BASS/TREBLE)

Perform trimming again.

the right and left speakers differs.

adjustments for the left and right channels

 

are different.

 

Left and right channels are

Connection of left and right speaker cables or

Make connections properly.

reversed.

input cables is reversed.

 

Sound is monaural.

The MODE switch on the rear panel is set to

Turn the unit off, set the MODE switch to

“BI-AMP”.

STEREO, then turn the unit back on.

 

 

Grounding connection from the record player

Check the connections to the PHONO GND

 

is improper.

terminal.

Noise occurs during record

Connection to the PHONO input jacks is

C h e ck t h e P H O N O i n p u t t e r m i n a l

incomplete.

connection.

playing.

 

 

A TV set, etc. placed too close to the record

Place the TV set or record player in another

Or, no sound is heard.

player may affect the sound.

position.

 

 

The PHONO MC button on the front panel is

Set the PHONO MC button properly.

 

not set properly for the cartridge used.

 

 

The record player and speakers are placed

Place the speakers as far away from the record

Howling occurs when sound volume

too close.

player as possible.

 

If an insulating pad is not supplied with the

is increased during record playing.

The record player is placed on a rack or floor

 

prone to vibration.

record player, use an insulating pad available

 

on the market.

 

 