RS-232C Control Specification

Page: 4 / 19

Document Version [1.00]

3. Detailed Description

The interface specification between the product and a Host controller is described below.

3-1. Connection format

3-1-1. Physical connection

 

Host (Controller)

Slave (the product)

TxD

 

RxD

RxD

 

TxD

GND

 

GND

 

 

 

 

3-1-1-1. Data transmission sequence from Host to Slave Host (Controller)

(Serial setting <RS232C basic>)

Baud Rate

: 9600bps

Data Bits

: 8bit

Parity

: None

Stop bit

: 1bit

Handshaking

: None

Slave (The product)

TxD

RxD

RxD

TxD

1.Host starts a data transmission from TxD.

2.Host performs the data transmission of the number of required bytes, and ends a transmission.

3-1-1-2. Data transmission sequence from Slave to Host

 

Host (Controller)

 

Slave (The product)

TxD

RxD

RxD

TxD

1.Slave starts a data transmission from TxD.

2.Slave performs the data transmission of the number of required bytes, and ends a transmission.