ASSEMBLING AND ADJUSTING
c)Attach the cartridge that you attached in the previous
step to the tone arm.
Screw
Tone arm
Head shell
Cartridge
•When using the included cartridge
Attach to the front attachment hole position on the tone arm.
•When using a different cartridge
Attach the cartridge so that it is 32mm from the stylus tip.
32mm
d)Connect the 4 tone arm wires to their respective terminals on the attached cartridge.
For the included cartridge
White Red
Blue Green
When using a different cartridge, refer to the cartridge instruction manual to connect the wires.
Caution:
Be careful when connecting the wires, as they are thin and break easily.
It is easy to connect the wires if you use tweezers etc.
6. Adjusting arm balance
a)Remove the
b)Attach the counter weight to the back of the arm.
Counter weight
Tone arm
c)Remove the cartridge cover.
Cartridge cover
Caution:
Make sure that the cartridge stylus tip does not touch the turntable etc. and that the stylus tip does not get damaged.
7