IMPORTANT SAFETY INSTRUCTIONS

WARNING:

TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK

OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.Do not use this fan with any Solid-State Speed Control Device.

2.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

3.Before servicing or cleaning this unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally.

4.Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.

5.Sufficient air is needed for proper combustion and exhausting of gases through flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

6.CAUTION: For general ventilation use only! Do not use to exhaust hazardous or explosive materials and vapors.

7.When cutting or drilling into wall or ceiling, Do Not damage electrical wiring or other hidden utilities.

8.CAUTION: This unit has an unguarded impeller. Do not use in locations readily accessible to people or animals.

TOOLS AND MATERIALS REQUIRED

Tape Measure

Screw Driver

Saber or Circular Saw

Electric hand Drill

Electrical Connectors & Supplies as required

Hammer & Nails

2 x 6 and/or 2 x 4 Wood Framing Materials are required

 

2 x 2 Furring Strips as required

 

Shutter - See text under Specific Installation for proper shutter

 

Power Tools should display the U.L. Listing Mark

 

ADDITIONAL MATERIALS REQUIRED FOR WALL INSTALLATION ONLY

3/4” Plywood as required.

Door Case Molding or Equivalent

Wood Screws, Bolts, Nuts, Washers, Lock Washers as required.

 

CAUTION: CUTTING ROOF TRUSS IS NOT RECOMMENDED.

SHUTTERS TO BE USED

FAN

 

TYPE OF

OPENING FOR

OVERALL SIZE

 

CUT CEILING

MODEL

SHUTTER

INSTALLATION

SHUTTER

OF SHUTTER

FINISH

JOIST

 

 

 

 

 

 

 

2438

3224

HORIZONTAL

24” x 24”

26” x 26”

WHITE

YES

3038R

3230

HORIZONTAL

30” X 30”

32” X 32”

WHITE

YES

3038R

A3024

HORIZONTAL

3012” X 3312

32” X 36”

WHITE

NO

3638R

3236

HORIZONTAL

36” X 36”

38” X 38”

WHITE

YES

3038R

3130

VERTICAL

30” X 30”

3318” X 3318

ALUMINUM

N/A

3638R

3136

VERTICAL

36” X 36”

3914” X 3914

ALUMINUM

N/A

 

 

 

 

 

 

 

BE CAREFUL!

USE PROTECTIVE GLASSES AND FOLLOW ALL SAFETY RULES.

1

Page 2
Image 2
Marley Engineered Products 3038R Tools and Materials Required, Additional Materials Required for Wall Installation only

3038R, 3638R, 2438 specifications

Marley Engineered Products is renowned for its high-performance cooling solutions, and among its most notable offerings are the Marley 3038R, 3638R, and 2438 evaporative cooling towers. These models are designed with advanced technology and features that ensure efficient temperature regulation for various industrial applications, enhancing productivity while minimizing energy consumption.

The Marley 3038R and 3638R models are distinguished by their robust construction and innovative design. They are made from high-quality materials that withstand harsh environmental conditions, ensuring longevity and reliability. Both cooling towers incorporate a modular design that eases installation and maintenance, promoting operational efficiency. The Marley 3038R is ideal for medium to large industrial settings, while the 3638R caters to larger operations needing more substantial cooling capacity.

One of the standout features of these models is the use of advanced film fill technology, which enhances heat exchange efficiency. This technology maximizes water-to-air contact, promoting effective cooling with reduced water consumption. Furthermore, the fan systems in these cooling towers are equipped with high-efficiency motors that operate quietly while delivering optimal airflow, thereby minimizing power expenditure.

The Marley 2438 model is particularly notable for its compact design, making it suitable for applications where space is a constraint. Despite its smaller size, it maintains high performance levels comparable to its larger counterparts, ensuring that users do not compromise on cooling efficiency.

All three models utilize durable and corrosion-resistant components that extend their service life and reduce maintenance needs. The units are designed for easy access to critical components, making routine inspections and repairs more straightforward and less time-consuming.

Additionally, Marley Engineered Products stands out for its commitment to sustainability. These cooling towers incorporate features that optimize water usage and reduce environmental impact. The cooling solutions provide a reliable and eco-friendly alternative for users looking to meet stringent sustainability goals without sacrificing performance.

In summary, the Marley 3038R, 3638R, and 2438 cooling towers epitomize efficiency, durability, and advanced technology in industrial cooling solutions. With their robust construction, innovative fill design, and energy-efficient components, they are well-suited for a diverse range of applications, making them a top choice for industries seeking reliable cooling performance. Whether for large-scale operations or space-limited environments, Marley Engineered Products delivers cutting-edge solutions to meet the demands of modern industry.