120V SUPPLY AVAILABLE AT CONTROL

FIG. 15

FAN MOTOR OUTLET BOX

CONTROL OUTLET BOX

 

MOTOR

BLACK (HI)

BLACK (HI)

CONTROL

 

BLUE (MED)

BLUE (MED)

 

 

 

 

RED (LOW)

RED (LOW)

 

 

WHITE (COM)

BROWN

 

 

 

BLACK

 

 

 

WHITE

120V, 60 HZ

 

GND. SCREW

 

 

120V SUPPLY AVAILABLE AT CONTROL

STEP 4 - After determining which diagram applies, pull wires to fan. Be sure to secure cable at fan to pre- vent it being caught in the blade. Make connections to fan and control. After wiring of fan and control is completed and checked against the appropriate wiring diagram, replace outlet box cover on fan and secure control in switch box. Leave control in “OFF” position.

WALL INSTALLATION (MODELS 3038R AND 3638R ONLY)

THIS INSTALLATION IS TO BE USED ONLY IN AN ATTIC GABLE OR WALL WHICH FACES AN UNOCCUPIED AREA, AN AREA NOT READILY ACCESSIBLE TO PEOPLE OR ANIMALS. (DO NOT USE THIS INSTALLATION IN AN ATTIC WITH ANY TYPE OF LOOSE INSULATION.)

All fans are factory assembled for ceiling installation and can be easily modified for wall mounting. The following steps describe this procedure and installation.

STEP 1—Reverse rotation of motor by reversing yellow and purple lead connections in conduit box on motor.

STEP 2—Remove blade by first loosening the two set screws in the hub. Now reverse the blade and reinstall onto motor shaft. Hub should be flush with the end of the motor shaft. Be sure set screws align with flats on shaft, then tighten bolt securely (150 lbs. of torque recommended).

STEP 3—Construct wood frame as shown in Fig. 1. Use 2” x 4” or 2” x 6” (depending on thickness of wall where unit is to be mounted) framing lumber.

“A”

SEE CHART

“B”

SEE

CHART

4” OR 6” —

DEPENDING ON THICKNESS OF WALL

FIG. 1

FIG. 2

DRILL (4) - 1/4” HOLES - (1) IN CENTER OF EACH

FIG. 3

SECURE SHUTTER IN PLACE

 

 

 

WITH WOOD OR LAG SCREWS

 

 

FLANGE AS SHOWN.

 

 

 

 

 

STEP 4—Drill (4) holes in fan housing as shown in Fig. 2.