FIG. 15 | FAN MOTOR OUTLET BOX | CONTROL OUTLET BOX |
|
MOTOR | BLACK (HI) | BLACK (HI) | CONTROL |
| |||
BLUE (MED) | BLUE (MED) |
| |
|
| ||
| RED (LOW) | RED (LOW) |
|
| WHITE (COM) | BROWN |
|
|
| BLACK |
|
|
| WHITE | 120V, 60 HZ |
| GND. SCREW |
|
|
120V SUPPLY AVAILABLE AT CONTROL
STEP 4 - After determining which diagram applies, pull wires to fan. Be sure to secure cable at fan to pre- vent it being caught in the blade. Make connections to fan and control. After wiring of fan and control is completed and checked against the appropriate wiring diagram, replace outlet box cover on fan and secure control in switch box. Leave control in “OFF” position.
WALL INSTALLATION (MODELS 3038R AND 3638R ONLY)
THIS INSTALLATION IS TO BE USED ONLY IN AN ATTIC GABLE OR WALL WHICH FACES AN UNOCCUPIED AREA, AN AREA NOT READILY ACCESSIBLE TO PEOPLE OR ANIMALS. (DO NOT USE THIS INSTALLATION IN AN ATTIC WITH ANY TYPE OF LOOSE INSULATION.)
All fans are factory assembled for ceiling installation and can be easily modified for wall mounting. The following steps describe this procedure and installation.
STEP
STEP
STEP
“A”
SEE CHART
“B”
SEE
CHART
4” OR 6” —
DEPENDING ON THICKNESS OF WALL
FIG. 1 | FIG. 2 | DRILL (4) - 1/4” HOLES - (1) IN CENTER OF EACH | FIG. 3 | SECURE SHUTTER IN PLACE |
|
|
| WITH WOOD OR LAG SCREWS | |
|
| FLANGE AS SHOWN. |
| |
|
|
|
|
STEP
11