![SURFACE MOUNTING](/images/new-backgrounds/43931/439315x1.webp)
SURFACE MOUNTING
1.The Surface Mounting Kit come in separate carton which contain two side frames, two end frames, and eight assem- bly screws.
2.Assemble the end frames to the side frames using the
screws provided (see Fig. 4) before installing on the ceiling.
CAUTION !
To prevent possible injury from falling panels, use at least four screws (1/4" or 0.635 minimum diameter) to secure each side frame. Screws must thread securely into a sturdy structural member of the ceiling, such as a ceiling joist. It may be necessary to
smaller than 2"x 4" (5cm x 10cm) for support. Use screws no smaller than number 10 in each hole provided in side and
end frames.
Fig. 6
Fig. 4
3.Mounting the frame assembly to the ceiling.
4.Remove one end frame and install heater panel in side frames as shown in Fig. 5.
CAUTION
Be sure electricity is turned off at main switch before wiring to prevent possible injury from electric shock.
5. Connect the heater panel leads to the power supply leads
(see Fig. 3 and WIRING instructions). The heater must be properly grounded as a precaution against electrical shock.
Use a properly grounded junction box for connecting the heater to the power supply. The heater may be moved along side frames to facilitate wiring.
6.
Fig. 5
CAUTION !
Failure to mount this kit securely may result in serious personal injury from falling heat panels.
RECESS MOUNTING
1.The Surface Mounting Kit come in separate carton which contain four frame sections and four corners (See Fig. 6).
2.Recessed heater panels require a cutaway in ceiling and a secure method of support (see Fig. 7). Use boards no
3.Insert the heater panel through the opening (see Fig. 7) and make wiring connections (see Fig. 3 and WIRING instruc- tions). The heater must be properly grounded as a precau-
tion against electrical shock. Use a properly grounded junc- tion box for connecting the heater to the power supply.
CAUTION
Be sure electricity is turned off at main switch before wiring to prevent possible injury from electric shock.
A
Fig. 7
4.Loosely screw side and end frames to ceiling opening, then attach corners in place (see Fig. 8).
5.After attaching corners, tighten screws securely.
6.Carefully lower heater panel in place on frames.
Fig. 8
3