![Electric Radiant](/images/new-backgrounds/43931/439311x1.webp)
Electric Radiant
Ceiling Heat
Panels
FILE #E21069
Installation & Maintenance Instructions
a
Dear Owner,
Congratulations! Thank you for purchasing this new heater manufactured by a division of Marley Engineered Products. You have made a wise investment selecting the highest quality product in the heat- ing industry. Please carefully read the installation and maintenance directions shown in this manual. You should enjoy years of efficient heating comfort with this product from Marley Engineered Products . . .
the industry’s leader in design, manufacturing, quality, and service.
. . . The Employees of
Marley Engineered Products
a
|
|
|
|
|
|
|
|
|
|
|
|
| ! |
| WARNING |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
Read Carefully - These instructions are written to help you prevent |
| When | T | The | ||||||
difficulties that might arise during installation of heaters. Studying the |
| secured to the building to provide adequate support for the pan- | ||||||||
instructions first may save you considerable time and money later. |
| els. Holes are provided in the sides of each panel for attachment | ||||||||
Observe the following procedures and cut your installation time to a |
| of steel support wires for additional support of the panels where | ||||||||
minimum. |
| the | ||||||||
|
|
|
|
| must be steel and at least 18 gage (0.047 in. dia. / 0.119 cm. dia). | |||||
1. | To prevent possible electrical shock, disconnect ALL power com- |
| When Surface or Recess Mounted: | The surface or recess mount- | ||||||
|
|
|
|
|
|
|
|
|
| |
| ing to heater at main service panel before wiring or servicing. |
| ing frame accessory kits (Models ASF . . . or ARF . . . ) must be | |||||||
2. | All wiring must be in accordance with the National and Local |
| used. Kits must be sized to match heaters being used. Do not | |||||||
| Electrical Codes and the heater must be grounded as a precau- |
| drill holes, drive nails, screws, etc., into or through panels. To do | |||||||
| tion against possible electrical shock. |
| so may result in fire, electric shock, or permanent damage to | |||||||
3. Verify the power supply voltage coming to the heater matches the |
| heater. Surface or recess kits must be securely fastened to build- | ||||||||
| ratings printed on the heater nameplate before energizing. |
| ing structure using a minimum of four (4) 1/4 inch (.635 cm) diam- | |||||||
4. | This heater is NOT suitable for use in hazardous locations as |
| eter screws or bolts. |
|
| |||||
| described by the National Fire Protection Association (NFPA). | 6. | To prevent possible fire due to the overheating of wiring, all field | |||||||
| DO NOT use in areas where gasoline, paint or other flammable |
| wiring coming to heating panels must be rated at least 90° C | |||||||
| liquids are used or stored. DO NOT use in wet areas or areas |
| when junction box is allowed to lie on top of heating panel or is | |||||||
| where corrosive agents are present, such as marine, green |
| enclosed between heater and ceiling above. When thermal insu- | |||||||
| house, chemical storage, swimming pool, or areas of high |
| lation is used on top of heater, the junction box must be above | |||||||
| humidity, unless special custom panels are used. Special custom |
| the insulation. |
|
| |||||
| panels may be available for certain environments. Contact manu- | 7. | Panels are intended for ceiling installation only. Do not install on | |||||||
| facturer for details. |
| walls, floor, etc. Painted (bottom) surface of panel is hot. Panels | |||||||
5. | To prevent a possible injury or fire from falling panels, panels |
| must be installed at least seven (7) feet off floor and should not | |||||||
| MUST be securely fastened to the building structure. |
| be installed where panels can be easily contacted during use. | |||||||
|
|
|
|
|
|
|
|
|
|
|
GENERAL
Marley Engineered Products Radiant Heating Panels are designed to provide comfort by warming the surfaces below the heaters just as the sun warms surfaces through radiant energy. This heating process heats objects in a room without having to bring the room air temperature up to the same level. These panels are ideal for spot heating in high heat loss areas. Panels may be installed side by side or individually above areas requiring additional heat. If used as a sole source of heat, more heat will be felt while standing directly under the panel.
Although the heater contains thermal insulation, it will operate more efficiently in well insulated rooms. Four or more inches of insulation above an exposed ceiling will increase both comfort and economy.
The heaters are intended to be controlled by a remote wall mounted thermostat. The thermostat should be located in the same room on a side wall. It should also be above five feet above the floor, but not directly under the heater.
SAVE THESE INSTRUCTIONS
1