BRICK PANEL INSTALLATION

INSTALLATION

BRICK PANEL INSTALLATION

Must install 1 set of brick panels with the P40.

1)Unwrap the Brick Panels from the protective wrapping.

2)Ensure that the logs are not in the unit.

3)Place the 2 small Back Brick Panels at the base of the firebox on the left and right side of the burner assembly.

Note: Ensure that the full brick pattern is on the bottom and the half brick pattern is on top to line up (approximately) with grout lines on side brick panels.

6)Place the Top Brick Panel over the back brick panel and secure with the top brick panel bracket.

Top Brick Panel

Bracket

Top Brick Panel

INSTALLATION

 

 

7) Remove the screw on the left side of the firebox. Place the left side

 

 

brick panel in position and secure using the brick tab and screw. Repeat

 

 

for right side brick panel.

Left Side Small

Right Side Small

 

Back Brick Panel

Back Brick Panel
Brick Tab

4)Insert the Back Brick Panel by slipping it between the back wall of the firebox and the burner assembly, sitting it on the small back brick panels installed in step 3.

Back Brick Panel

Brick Panels Completely Installed

5)Remove the Top Brick Panel Bracket by removing the 3 screws.

IMPORTANT

Dangerous operating conditions may occur if the panels are broken.